Owner's manual

Command Reference
Beijer Electronics, MAEN975 47
6.14 TYP
Unit Type and Model Number
Queries the monitor type and model.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
(This command has no data)
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
(No data is returned, in case of a negative acknowledge)
Maximum Lr for this Command
23
Example
Query the unit type and model of the monitor at address 0.7 (group 0, address 7):
According to the data returned by the monitor at address 0.7 (group 0, address 7),
this is a Beijer Electronics Nautic Monitor:
0 1 2 3 4 5 6
0x07 ADR
0x54 0x59 0x50 0x01 ICHKH
0 1 2 3 4 5 6 7...7+[LEN]-1 7+[LEN]
0x06 ADR 0x54 0x59 0x50 LEN ICHKH Type/Model ICHKD
Type/Model
Value: ASCII characters
Type: String
Length: 1...15
Description: Monitor type and model
0 1 2 3 4 5 6
0x15 ADR
0x54 0x59 0x50 0x00 ICHKH
0 1 2 3 4 5 6
0x07 0x07 0x54 0x59 0x50 0x00 0xF4
0 1 2 3 4 5 6 7-20
0x06 0x07 0x54 0x59 0x50 0x0E 0xE7 0x4D 0x54 0x32 0x32
7-20 21
0x33 0x20 0x4E 0x41 0x56 0x2D 0x32 0x33 0x30 0x47 0xB9