6.51 LAU_CONFIG_GETBRTRANGEDELTAP
(0x0123)
Backlight Level Up Range
By default, the backlight level of a Beijer Electronics Nautic Monitor can be changed
within the full range of 0 to 255 steps by using the front panel keys. To allow the
backlight level change within a limited range, a delta value can be defined. The delta
value sets the upper and lower backlight level range limits relative to the ECDIS
backlight value (which is set by the SCOM command “BRT”). Normally, upper and
lower range limits are defined as 255 for full range support. The value returned by
this command is the upper range limit relative to the ECDIS backlight level.
Supported since Firmware Version
MT230 Nautic Monitor: 1.0
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
0 1 2 3 4 5 6 7...8 9
0x07 ADR
0x4C 0x41 0x55 0x02 ICHKH 0x01 0x23 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR
0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0...255
Type: Byte
Length: 1
Description: Upper backlight level range limit relative to the ECDIS
backlight level