Owner's manual

Command Reference
Beijer Electronics, MAEN975 93
6.53 LAU_CONFIG_GETDISPLAYGROUP
(0x0127)
Monitor Group
Besides the standard addressing scheme, where the lowest four address bits in field
ADR are used to address a total count of 16 monitors in a network, the Beijer Elec-
tronics Nautic Monitors use also the upper four bits, that indicate a group of moni-
tors in a network (max. 14 groups). The monitor grouping is activated, if the
software configured monitor address is used (i.e. the DIL/DIP switch settings are ig-
nored). This function returns the configured group that the monitor belongs to.
Supported since Firmware Version
MT230 Nautic Monitor: 1.2-C118
Command Stream
Response Message (Acknowledge)
Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.
Maximum Lr for this Command
9
Example
Read the software configured display group from the monitor at address 14.7 (group
14, address 7), which is effective, if the DIL switch settings are ignored:
According to the data returned by the monitor at address 14.7 (group 14, address 7),
the monitor belongs to display group 14 (0x0E), if the DIL switch settings are ig-
nored:
0 1 2 3 4 5 6 7...8 9
0x07 ADR 0x4C 0x41 0x55 0x02 ICHKH 0x01 0x27 ICHKD
0 1 2 3 4 5 6 7 8
0x06 ADR 0x4C 0x41 0x55 0x01 ICHKH Ret ICHKD
Ret
Value: 0...14
Type: Byte
Length: 1
Description: Configured display group
0 1 2 3 4 5 6 7...8 9
0x07 0xE7
0x4C 0x41 0x55 0x02 0x2D 0x01 0x27 0xD7
0 1 2 3 4 5 6 7 8
0x06 0xE7 0x4C 0x41 0x55 0x01 0x2F 0x0E 0xF1