RFID MODULE Mifare Reader / Writer SL030 User Manual Version 3.
StrongLink SL030 3.1 CONTENT 1. MAIN FEATURES .................................................................................. 3 2. PINNING INFORMATION ................................................................... 4 3. Device Operation ..................................................................................... 5 3-1. 3-2. 3-3. 3-4. 3-5. 3-6. 3-7. 3-8. CLOCK AND DATA TRANSITIONS: ..........................................................................................
StrongLink SL030 3.1 1. MAIN FEATURES *This picture may not be exactly the same as real object. • Tags supported: Mifare 1k, Mifare 4k, Mifare UltraLight, Mifare UltraLight C, NTAG203, DESFire, DESFire EV1 and Mifare Plus 2K/4K • Built-in antenna • 0 to 400 KHz bit-wide I2C-bus communication • 2.7 ~ 3.6V VDC operating, I/O pins are 5V tolerant • Work current less than 45mA @3.
StrongLink SL030 3.1 2. PINNING INFORMATION PIN SYMBOL TYPE DESCRIPTION Power supply, 2.7V to 3.6VDC Falling edge wake up SL030 from power down mode Serial Data Line Serial Clock Line Tag auto-detection signal low level indicating tag in high level indicating tag out Ground 1 2 3 4 VDD IN SDA SLC PWR Input Input/Output Input 5 Out Output 6 7 8 9 10 GND NC NC NC NC PWR Attention: Pin IN must be connected HIGH voltage when working, so SL030 can enter power down mode properly. http://www.
StrongLink SL030 3.1 3. Device Operation 3-1. Clock and Data Transitions: The SDA pin is normally pulled high with an external device. Data on the SDA pin may change only during SCL low time periods. Data changes during SCL high periods will indicate a start or stop condition as defined below. 3-2. Start Condition A high-to-low transition of SDA with SCL high is a start condition which must precede any other command 3-3. Stop Condition A low-to-high transition of SDA with SCL high is a stop condition.
StrongLink SL030 3.1 3-5. Busy State When the SL030 has received command, then don’t acknowledge IIC bus until ends with the card communication. 3-6. Device Addressing The SL030 devices require an 8-bit device address word following a start condition to enable the chip for a read or write operation. The device address word consists of 7 bits addressing and 1 bit operation select bit.
StrongLink SL030 3.1 3-7. Write Operations The host device send a command(refer chapter 4) to SL030 via write operation, then SL030 will carry out the order that receive. Finished time according to different order 3-8. Read Operations The host device passes to read the operation gets the order carries out the result 4. COMMAND DESCRIPTION 4-1.
StrongLink SL030 3.1 4-2.
StrongLink SL030 3.1 4-3. COMMAND LIST 4-3-1.
StrongLink SL030 3.1 Host Write: Len 0x12 Sector Type Key Sector: 0x00 – 0x27 Type: Key type (0xAA: KeyA, 0xBB: KeyB) Key: 6 bytes, stored into SL030 Host Read: Len 0x12 Status Status: 0x00: Operation succeed 0x08: Address overflow 0x09: Download fail Note: Some delay is needed between Host Write and Host Read. 4-3-4.
StrongLink Data: SL030 3.1 0x01: No tag 0x05: Write fail 0x06: Unable to read after write 0x0D: Not authenticate Block data written if operation succeeds, 16 bytes. 4-3-7. Read a value block Host Write: Len 0x05 Block Block: The absolute address of block to be read, 1 byte. Host Read: Len 0x05 Status Value Status: 0x00: Operation succeed 0x01: No tag 0x04: Read fail 0x0D: Not authenticate 0x0E: Not a value block Value: Value returned if the operation succeeds, 4 bytes. 4-3-8.
StrongLink SL030 3.1 0x08: Address overflow 0x0D: Not authenticate Key: Authentication key written if the operation succeeds, 6 bytes. Attention: Be sure KeyB is readable, otherwise KeyB will be change to 000000000000 after this command. 4-3-10. Increment value Host Write: Len 0x08 Block Value Block: The absolute address of block to be increased, 1 byte. Value: The value to be increased by, 4 bytes.
StrongLink SL030 3.1 Len 0x0A Status Value Status: 0x00: Operation succeed 0x01: No tag 0x05: Write fail 0x06: Unable to read after write 0x0D: Not authenticate 0x0E: Not a value block (Source) Value: The value after copy if the operation succeeds, 4 bytes 4-3-13.
StrongLink SL030 3.1 4-3-16. Exchange Transparent Data (T = CL) Len 0x21 Data Data: COS command Response: Len 0x21 Status Data Status: 0x00: Operation succeed 0x11: Communicate with card failed Data: Response data from card 4-3-17. LED Control Host Write: Len 0x40 Data Data: 0x00: LED off 0x01: LED on Host Read: Len 0x40 Status Status: 0x00: Operation succeed 4-3-18. Power Down Host Write: Len 0x50 Host Read: Len 0x50 Status Status: 0x00: Operation succeed Note: Some delay is needed when waking up SL030.
StrongLink SL030 3.1 4-3-20. Commit Perso Host Write: Len 0x81 This command commit the Write Perso and switch the card to security level 1(SL1 card) or level 3(SL3 card). Host Read: Len 0x81 Status Status: 0x00: Operation succeed 0x11: Communicate with card failed 0x13: Card Commit Perso failed Attention: According to NXP MifarePlus card document, Commit Perso will make effect after you have “Write Perso” the Master KEY, Configuration KEY and SWL3 KEY.
Federal Communications Commission (FCC) Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
OEM Integration Instructions: This device is intended only for OEM integrators under the following conditions: The module can be used to installation in other host. The antenna must be installed such that 20 cm is maintained between the antenna and users, and the transmitter module may not be co-located with any other transmit or antenna. The module shall be only used with the integral antenna(s) that has been originally tested and certified with this module.