Users Manual Part 1

30
6. Click the dropdown menu in the upper left to shift to X/Z mode. X/Z calibration
requires measurement of the L-shapes.
Only one L-shape is needed to do the measurement, but all the L-shapes are
needed to check in order to find the right one.
First, remove all the L-shapes from the build plate and peel them off the raft.
Rememer the position of each L-shape on the build plate when peel them off the
build plate.
Place them in a position on a table that matches their original position on the print
surface right for right, front for front, etc.
Use a right angle ruler as shown in the following Figure and push the ruler against
the corner of each one of the L-shapes. If the angle of the corner of the L-shape is
90 degrees, move to the next L-shape. Continue this process with each L-Shape. If
all the L-shapes are 90 degrees as shown in figures 3 and 4, enter ‘0.0’ for the Z
value and X/Z calibration is done.
If you find one L-shape that is not 90 degrees, it means the X and Z axis are not
perpencular, and it needs to be adjusted. To clarify, you need to look for a gap
between the ruler and the L-shaped object. If you find a gap, you have found the L-
shape that will provide your Z value and so you need to measure the gap.
The gap will either be at the top of the L-Shape (an obtuse angle) or at the bottom
corner(an acute angle), between the ruler and L-Shape. Use another ruler to
measure the gap, as shown below. Enter the Z value as a negative number if the
angle is obtuse. Enter the Z value as a positive number if the angle is acute.