Operating instructions

Electrical installation
BEKOSPLIT® 11 19
If operating voltage is applied
, and if
the BEKOSPLIT is in standby in the
AUTO mode (start sensor uncovered),
the KR2 relay will become operative.
The contact (terminals 23-24) is
closed.
Without operating voltage, in the
STOP mode or during functioning in
the AUTO mode, relay KR2 will drop
off. The contact (terminals 23-24) is
open.
For installation, remove the protective
caps of the front panel, unscrew the
screws, and remove the cover of the
housing.
Only a low voltage must be applied to
the contacts of KR1 and KR2.
The relay contacts can optionally be
used as normally closed or normally
open contacts.
When using the signal connections,
sufficient clearance to the other parts
of the unit carrying supply voltage, or
suitable insulation must be ensured.