Instructions Manual CTB 6407 - CTB 9407
INDEX EN RECOMMENDATIONS AND SUGGESTIONS ..................................................................................................................... 3 CHARACTERISTICS ............................................................................................................................................................. 4 INSTALLATION.................................................................................................................................................................
RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION • The manufacturer will not be held liable for any damages resulting from incorrect or improper installation.
CHARACTERISTICS 175 ø 120 598 280 - 898 Min. Min. 650mm 650mm 0÷152 Components Ref. 1 8 20 Q.ty 1 1 1 Product Components Hood Body, complete with: Controls, Light, Blower, Filters Directional Air Outlet grille Closing element Ref. 12a 12e Q.ty Installation Components 4 Screws 4,2 x 44,4 2 Screws 2,9 x 9,5 12e 8 12a 1 20 Q.
INSTALLATION Drilling the Support surface and Fitting the Hood 12a 125 135 SCREW FITTING • The hood support surface must be 135 mm above the bottom surface of the wall units. • Drill the support with a ø 4,5 mm drill bit, using the drilling template provided. • Cut a hole ø 125 mm in size on the support surface, using the drilling template provided. • Fix using the 4 screws 12a (4,2 x 44,4) provided.
Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø120 mm, the choice of which is left to the installer. • Fix the pipe in position using sufficient pipe clamps (not supplied). • Remove any activated charcoal filters. • • • • • RECIRCULATION VERSION AIR OUTLET Cut a hole ø 125 mm in any shelf that may be positioned over the hood.
USE Control panel L M-V 0 1 3 2 1 0 M-V L L Light M Motor V Speed EN Switches the lighting system L on and off. Switches the extractor motor M on and off. Sets the operating speed of V the extractor: 1. Low speed, used for a continuous and silent air change in the presence of light cooking vapour. 2. Medium speed, suitable for most operating conditions given the optimum treated air flow/noise level ratio. 3.
MAINTENANCE Grease filters CLEANING METAL CASSETTE GREASE FILTERS • The filters must be cleaned every 2 months, or more frequently in case of particularly heavy use of the hood. Filters can be washed in a dishwasher. • Pull out the sliding suction panel. • Remove the filters one by one, after having disconnected the relative fastening elements. • Wash the filters, taking care not to bend them. Let them get dry before refitting them.
EN 9 9
EN 1 10
EN 1 11
EN 1 12
436005809_ver1