Service manual

Belarus 80.1/80.2/82.1/82.2/82Р Operation and Service Manual
Section 9. Storage Rules for Tractors
119
9. STORAGE REGULATIONS FOR THE TRACTOR
Tractors in the economies are subject to
storing in autumn-winter periods, as well
as during field operation as per GOST
ГОСТ 7751-85 and GOST 9.014-78.
9.1. GENERAL PROVISIONS
9.1.1 The tractor can be placed for:
inter-seasonal storage up to 10
day of downtime;
short-term storage downtime
from 10 days to two months;
long-term storage more than two
months of downtime.
9.1.2. During the autumn-winter period
keep the tractor indoors or under a shed.
Tractors can be stored outdoors, on a
specially prepared storage yard, subject
to mandatory preservation, sealing and
stripping of components and assembly
units which require warehousing, in
compliance with the requirements of
GOST ГОСТ 7751-85.
9.1.3. Maintenance servicing of tractors
intended for storing shall be carried out
according to the current practice ap-
proved in the economy.
9.1.4. For an inter-shift or short-term
storage the tractor should be placed im-
mediately on completion of works, and
for a long-term storage not later than
10 days after termination of employment.
9.2. INTER-SEASONAL STORAGE
REGULATIONS (up to 10 days)
9.2.1. Place the tractor complete in a
storage area.
9.2.2. All the openings which are likely to
serve as inlets to tractor inner spaces for
atmospheric precipitation, should be
tightly stopped with caps, plugs or tar-
paulin jackets.
9.2.3. The storage batteries should be
disconnected.
9.3. SHORT-TERM STORAGE REGU-
LATIONS (from 10 days to 2 months)
9.3.1. Preparation for storage is carried
out in accordance with recommendations
in 9.4., except items 9.4.1.c 9.4.1.i.
9.3.2. The tractor is placed complete, in
operating order, without any unit or as-
sembly dismantled; with no need for
covering the tyres and rubber hoses with
light-protective compounds. Wrap the
exhaust pipe and thee monocyclon in
polyethylene film.
9.3.3. Disconnect the storage batteries.
The electrolyte level and density should
conform with the recommendations spec-
ified in subsection "Servicing and Check-
ing Storage Batteries".
When storing the tractor at low tempera-
tures or for a period exceeding one
month, remove the storage batteries and
keep them in a warehouse.
9.4. LONG-TERM STORAGE REGU-
LATIONS (more than 2 months)
9.4.1. Before placing the tractor for stor-
age, proceed with the operations as fol-
lows:
а) clean and wash the tractor, restore
disturbed or damaged patches of
paintwork;
b) drain coolant from the diesel-engine
cooling system, drain water from the
small-scale cab heating/cooling unit
water container (if installed); drain
sediment from the coarse and fine
fuel filter bowls;
c) drain oil from the diesel-engine
crankcase, fuel pump body, clean
the centrifugal oil filter rotor;
d) fill the diesel-engine crankcase, fuel
pump body with slushing oil with 5 %
additive АКОР-1 GOST 15171-78.
When additive АКОР-1 is used, pre-