Product description
Description Entry Level Industrial ETHERNET Rail Switch,
store and forward switching mode,
Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation,
auto-polarity
1 x 100BASE-FX, MM cables, SC sockets
Type SPIDER 4TX/1FX
Order No. 943 221-001
More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 3-pin, no signal contact
Network size - length of cable
Twisted pair (TP) 0 - 100 m
Multimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,
11 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Network size - cascadibility
Line - / star topology Any
Power requirements
Operating voltage 9,6 V DC - 32 V DC
Current consumption at 24 V DC Max. 150 mA
Power consumption Max. 3,9 W 13,3 Btu (IT)/h at 24 V DC
Service
Diagnostics LEDs (power, link status, data, data rate)
Ambient conditions
Operating temperature 0 °C to +60 °C
Storage/transport temperature -40 °C to +70 °C
Relative humidity (non-condensing) 10% to 95%
MTBF 112.0 years; MIL-HDBK 217F: Gb 25 °C
Mechanical construction
Dimensions (W x H x D) 25 mm x 114 mm x 79 mm
Mounting DIN Rail 35 mm
Weight 120 g
Protection class IP 30
Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks
IEC 60068-2-6 vibration 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz)
EN 61000-4-4 fast transients (burst) 2 kV power line, 4 kV data line
EN 61000-4-5 surge voltage Power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line
EN 61000-4-6 conducted immunity 10 V (150 kHz - 80 kHz)