Data Sheet

3
Mechanical Data Profinet Type C
Part
Part Part
Part
Number
NumberNumber
Number
Conductor
ConductorConductor
Conductor
Polyolefin
Polyolefin Polyolefin
Polyolefin
Insulation
Insulation Insulation
Insulation
(Nom. Dia.)
(Nom. Dia.)(Nom. Dia.)
(Nom. Dia.)
Bedding
Bedding Bedding
Bedding
Material
Material Material
Material
(Nom. Dia.)
(Nom. Dia.)(Nom. Dia.)
(Nom. Dia.)
Braid
Braid Braid
Braid
Coverage
CoverageCoverage
Coverage
Sheath
Sheath Sheath
Sheath
Material
MaterialMaterial
Material
Sheath
Sheath Sheath
Sheath
(Nom. Dia.)
(Nom. Dia.)(Nom. Dia.)
(Nom. Dia.)
70008PU 22AWG/19 1.63mm
PVC 4.30mm >85% PUR 6.50mm
Electrical Properties
ISO/IEC 11801 ed. 2.0, Cat5e
Max Operating Voltage
300V RMS
Test Voltage
2.5kV DC
Max Conductor Resistance @ 20
o
C
57.1 Ohm / km
Transfer Impedance @ 10 MHz
< 40 mOhm / m
Nominal Velocity of Propagation
68%
Delay
< 5.3 ns / m
Impedance @ 1 – 100 MHz
100 +/- 15 Ohm
Frequency
Frequency Frequency
Frequency
(MHz)
(MHz)(MHz)
(MHz)
Insertion Loss
Insertion LossInsertion Loss
Insertion Loss
(dB/100m)
(dB/100m)(dB/100m)
(dB/100m)
NEXT
NEXT NEXT
NEXT
(dB)
(dB)(dB)
(dB)
ELFEXT
ELFEXT ELFEXT
ELFEXT
(dB/100m)
(dB/100m)(dB/100m)
(dB/100m)
RETURN
RETURN RETURN
RETURN
LOSS (dB)
LOSS (dB)LOSS (dB)
LOSS (dB)
1
2.1
65
64
-
4
4
56
52
23
10
6.3
50
44
25
16
8
47
40
25
31.25
11.4
43
34
23.6
62.5
16.5
38
28
21.5
100
21.3
35
24
20.1
Mechanical, Physical and/or Environmental Characteristics
Flame Resistance
IEC60332-1
Oil Resistance
IEC 60811-2-1
Halogen Free
IEC 60754-1 / IEC 60754-2 (FRNC and PUR Cable Jacket)
Bending Radius / Setting Radius
10 x Diameter / 5 x Diameter
Temperature Range - Installation
- 5
o
C to +50
o
C
Temperature Range - Operating
-40
o
C to +80
o
C
Version 04 (02/11)
Foil + Braid
Bedding
Sheath (Green RAL 6018)
Conductor (22AWG/19 19x0.15mm stranded tinned copper)
Filler
Insulation