Datasheet

28 AWG Stranded (7x36) TC Conductors • Overall Beldfoil
®
(100% Coverage) + TC Braid Shield (65% Coverage) • 28 AWG Stranded TC Drain Wire
Datalene
®
Insulation • Chrome PVC Jacket
UL AWM Style 2919 8132 NEC: 2 See 100 30.5 3.6 1.6 65.0/M 5.1/M .220 5.59 120 78% 11.0 36.1 20.0 65.6
(30V 80°C) CL2 Chart 5 500 152.4 14.5 6.6 213.0/km 16.6/km
(Tech Info 1000 304.8 29.0 13.2
Section)
8133 NEC: 3 See 100 30.5 3.8 1.7 65.0/M 5.2/M .270 6.86 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 500 152.4 15.0 6.8 213.0/km 17.1/km
(Tech Info 1000 304.8 34.0 15.5
Section)
8134 NEC: 4 See 100 30.5 4.3 2.0 65.0/M 4.4/M .290 7.37 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 500 152.4 18.0 8.2 213.0/km 14.3/km
(Tech Info 1000 304.8 39.0 17.7
Section)
8135 NEC: 5 See 100 30.5 4.6 2.1 65.0/M 4.2/M .300 7.62 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 1000 304.8 42.0 19.1 213.0/km 13.8/km
(Tech Info
Section)
8138 NEC: 8 See 100 30.5 5.6 2.5 65.0/M 3.7/M .330 8.38 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 500 152.4 27.0 12.3 213.0/km 12.3/km
(Tech Info 1000 304.8 52.0 23.6
Section)
8142 NEC: 12.5 See 100 30.5 6.8 3.1 65.0/M 3.1/M .375 9.53 120 78% 11.0 36.1 20.0 65.6
CL2
(12 pairs +
Chart 5 500 152.4 33.0 15.0 213.0/km 10.1/km
1 single)
(Tech Info 1000 304.8 66.0 29.9
Section)
8148 NEC: 18 See 100 30.5 8.5 3.9 65.0/M 2.6/M .465 11.81 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 500 152.4 47.5 21.6 213.0/km 8.4/km
(Tech Info 1000 304.8 92.0 41.8
Section)
8155 NEC: 25 See 100 30.5 11.1 5.0 65.0/M 2.3/M .565 14.35 120 78% 11.0 36.1 20.0 65.6
CL2 Chart 5 500 152.4 64.0 29.1 213.0/km 7.6/km
(Tech Info 1000 304.8 121.0 55.0
Section)
DCR = DC Resistance TC = Tinned Copper
*Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
Datalene insulation features include low dielectric constant and a
dissipation factor for high-speed, low-distortion data handling.
Physical properties include good crush resistance and light weight.
PAIRED CABLES
5.27
Overall Foil/Braid Shield
Low-Capacitance Computer Cables for EIA RS-232 and EIA RS-485 Applications
UL NEC/
C(UL) CEC
Type
Part
No.
No.
of
Pairs
Ft. m
Standard
Lengths
Standard
Unit Weight
Lbs. kg
Nom. DCR
Cond. Shield
Description
Color
Code
Nominal
OD
Inch mm
Nom.
Imp.
()
Nom.
Vel.
of
Prop.
Nom. Capacitance
*
pF/
Ft.
*
pF/
m
**
pF/
Ft.
**
pF/
m
5 Paired Cables
For more information, contact Belden Technical Support: 1-800-BELDEN-1 • www.belden.com
Shorting Fold