24 AWG stranded (7x32) TC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® (100% coverage) + TC braid
shield (90% coverage), 24 AWG stranded TC drain wire, PVC jacket.
AWG
# Pairs AWG Stranding Conductor Material
1.000 24 7x32 TC - Tinned Copper
Insulation Material
Insulation Material
PE - Polyethylene
Outer Shield Material
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Beldfoil® Tape Aluminum Foil-Polyester Tape 100
2
Braid TC - Tinned Copper 90
Outer Shield Drain Wire AWG
AWG Stranding Drain Wire Conductor Material
24 7x32 TC - Tinned Copper
Outer Jacket Material
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Nominal Diameter:
Pair Color Code Chart
Color
White/Blue and Blue/White
Pair Lay Length & Direction
Lay Length (in.) Twists/ft. (twist/ft) Direction
2.500 4.800 Left Hand Lay
Operating Temperature Range
UL Temperature Rating
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
Physical Characteristics (Overall):
Conductor:
Insulation:
Outer Shield:
Outer Jacket:
Overall Cabling:
0.232 in.
Mechanical Characteristics (Overall):
-30°C To +80°C
80°C
36 lbs/1000 ft.
72.300 lbs.
2.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards:
Page 1 of 3 07-04-2008