Brochure

4 13/32”
2 13/16”
4 3/8”
1/2” 14 NPT
9/16” 24 UNEF9/16” 24 UNEF
1/2” 14 NPT
1 19/32”
2 13/16”
7 7/16”
CIRCULATORS autocirc
®
Series
Potable Hot Water Recirculation Pumps - Undersink
11
Description
autocirc
®
FLUFXODWRUVDUHHQHUJ\HIŵFLHQWXVLQJSHUPDQHQWPDJQHW(&0
(electronically commutated motor) technology. The autocirc circulators
DUHGHVLJQHGVSHFLŵFDOO\IRUVWDQGDUGZDWHUKHDWHUV7KHVHFLUFXODWRUVDUH
lead-free* and are assembled with a timer, cord and plug.
&6$FHUWLŵHGWR16)$16,WKDWSURGXFWFRQWDLQVOHVVWKDQOHDGFRQWHQWE\ZHLJKWRQZHWWHGVXUIDFH
ecocirc B 23-5 ACT
Materials of Construction
Pump Body: Lead-Free* Brass
25LQJ(3'0
Bearing: Carbon/Ceramic
,PSHOOHU1\ORQ332
0RWRU+LJK(IŵFLHQF\(&0
$OO2WKHU:HWWHG3DUWV7\SH6WDLQOHVV6WHHO
Shaft-less and Seal-less construction.
Operating Data Pump
Maximum Working Pressure: 145 PSI (10 Bar)
Maximum Working Temperature: 203ºF (95ºC)
Minimum Working Temperature: 50ºF (10ºC)
Motor
ECM Spherical Motor
115 Volt 60 Hz, 1 Phase
14 Watts Power Consumption
$XWRPDWLF2YHUORDG3URWHFWLRQ
Low in-rush current
Model Number Part Number Description Weight
e
3
B%'34& /+% Lead-Free Brass autocirc 1/2” Fixed Thermostat with Timer 4 lbs.
e
3
B%'35& /+% Lead-Free Brass autocirc 1/2” Adjustable “ON” Thermostat with Timer 4 lbs.
e
3
-4_-/BDPQC
e
3
-4_-/BDPRC
Materials of Construction
Pump Body: Lead-Free* Brass
25LQJ(3'0
Bearing: Carbon/Ceramic
,PSHOOHU1\ORQ332
0RWRU+LJK(IŵFLHQF\(&0
$OO2WKHU:HWWHG3DUWV7\SH6WDLQOHVV6WHHO
Shaft-less and Seal-less construction
Operating Data Pump
Maximum Working Pressure: 145 PSI (10 Bar)
Maximum Working Temperature: 203ºF (95ºC)
Minimum Working Temperature: 50ºF (10ºC)
Description
7KHHFRFLUF%$&7OHDGIUHHSXPSZDVGHVLJQHGZLWKKLJKO\HIŵFLHQWHOHFWURQLFDOO\
FRPPXWDWHGSHUPDQHQWPDJQHWPRWRU(&030WHFKQRORJ\VSHFLŵFDOO\IRUSRWDEOHZDWHU
V\VWHPV7KLVXQLTXHGHVLJQLVSHUIHFWIRUUHWURŵWVDQGV\VWHPVZLWKWDQNOHVVZDWHUKHDWHUV
No recirculation pipe is required.
CIRCULATORS ecocirc
®
B 23-5 ACT
Potable Hot Water Recirculation Pumps - Undersink
Motor
ECM Spherical Motor
115 Volt 60 Hz, 1 Phase
60 Watts Power Consumption
$XWRPDWLF2YHUORDG3URWHFWLRQ
Low in-rush current
Model Number Part Number Description Weight
ecocirc B 23-5 ACT 6050B7016 Lead-Free Brass autocirc 1/2” Fixed Thermostat with Timer 6.50 lbs.
&6$FHUWLŵHGWR16)$16,WKDWSURGXFWFRQWDLQVOHVVWKDQOHDGFRQWHQWE\ZHLJKWRQZHWWHGVXUIDFH
6.76” (71.7mm)
5.85” (48.7mm)
1.61” (40.8mm)
5.97” (151.74mm)
5.19” (132mm)
2.32” (59mm)3.98” (101mm)