ŘIDFWRU\WHVWHGJXDUDQWHHVRSHUDWLRQ
Ř)LYH\HDUOLPLWHGZDUUDQW\WKHEHVWLQWKHEXVLQHVV
Ř5HSODFHDEOHVWDQGDUGœLFHFXEHŔW\SHUHOD\VDOORZXSWRDPSV
1/3 HP per individual zone
Ř6HOHFWDEOHSULRULW\IRUGRPHVWLFKRWZDWHU
ŘPLQXWHEXLOWLQSULRULW\WLPHUKHOSVSUHYHQWKRXVHIUHH]HXSQRDGGLWLRQDO
plug-in cards required
Ř$XWRPDWLFDOO\UHVHWDEOHIXVHSURWHFWVFRQWUROOHUIURPRYHUORDGHOLPLQDWHV
“no heat” call backs due to blown fuse
Ř3RZHUIXOWUDQVIRUPHUVRSHUDWHXSWRVL[]RQHV
Ř/('GLDJQRVWLFOLJKWVLQVWDOOHGLQWHUQDOWRWKHER[FRYHUNHHSVWKHWURXEOH
shooting in the hands of the authorized heating professionals
Ř&DQEHXVHGZLWKœWDQNOHVVFRLOŔRUœFROGVWDUWŔDSSOLFDWLRQV
Specifications
Specifications
RELAYS ZONETROL
Switching Relays
for Zoning with Valves
Features
Model No. Part No. Zones
Priority
Feature
Transformer
Output
at 24 Volts
Relay
Switching
Action
Each End
Switch Contact
Rating
Dimension
W x H x D (inches)
Approx.
Shpg. Wt.
(lbs.)
ZTV-4 109407 4 yes 40 VA DPDT
5A, 1/8 HP
@ 120VAC
9-1/4 x 7-1/4 x 2-3/4 4.6
ZTV-6 109408 6 yes 75 VA DPDT 11-3/8 x7-1/4 x 3-3/4 6.9
RELAYS ZONETROL II Switching Relays
with Reset Option for Zoning with Pumps
Description
Bell & Gossett’s ZoneTrol II is a ready-to-install controller for hydronic
circulators in residential and light commercial applications. All ZoneTrol II
controllers are UL and cUL listed and feature multi-function LEDs that are
visible without removing the cover for easy start-up and troubleshooting.
All units are compatible with analog and digital 24 VAC thermostats,
including “power stealing” designs. The multi-zone controllers feature an
advanced microprocessor design that provides domestic hot water (DHW)
priority & timer, pump exercise and a post purge timer without the need
for add-on circuit boards or modules.
Four and six zone controllers are field expandable for up to 18 pumps.
* fits 4 and 6 zone controllers only – one required for each slave controller.
Model
Number
Part
Number
Zones
Combined Load
(max.) @ 120 VAC
Dimensions W x L x D
Inches (mm)
Weight
Lbs (kg)
Z-1 109424 1 5 amps 6.5 x 5 x 3 (165 x 127 x 76) 2.6 (1.18)
Z-2 109425 2 20 amps 6.5 x 5 x 3 (165 x 127 x 76) 3 (1.36)
Z-3 109426 3 20 amps 6.5 x 5 x 3 (165 x 127 x 76) 3.1 (1.4)
Z-4 109427 4 20 amps 13.5 x 8.25 x 3.25 (343 x 210 x 83) 7.3 (3.3)
Z-6 109430
6
13.5 x 8.25 x 3.25 (343 x 210 x 83)
7.5 (3.4)
ZC-11* 109454
Communication cable for connection of multiple controllers
0.1 (0.05)
20 amps
Standard Features (multiple zone controllers only)
Ř3ULRULW\(QDEOHV'+:]RQHWRKDYHSULRULW\RYHUKHDWLQJ]RQHVIRUOLPLWHGSHULRGRIWLPH8VHUDGMXVWDEOHVHWWLQJVLQFOXGH2))GLVDEOHVSULRULW\
functionality), 30 minutes and 60 minutes.
Ř3RVW3XUJH7LPHU&LUFXODWRUVZLOOFRQWLQXHWRUXQIRUVHFRQGVDIWHUWKHUPRVWDWRSHQVDQGDOORZVDGGLWLRQDOH[WUDFWLRQRI%78VIURPKLJK
PDVVERLOHUV8VHUDGMXVWDEOHVHWWLQJVDUH2))DQG21
Ř([HUFLVH5XQVHDFKFLUFXODWRUIRUVHFRQGVDIWHUHDFKKRXUVRILQDFWLYLW\8VHUDGMXVWDEOHVHWWLQJVDUH21DQG2))
Ř([SDQGDELOLW\DQG]RQHFRQWUROOHUVFDQHDVLO\EHFRQQHFWHGYLDD=&FDEOHWRDFFRPPRGDWHV\VWHPVFRQVLVWLQJRIXSWRFLUFXODWRUV
Ř)LYH\HDU:DUUDQW\
The next generation of zone controllers
from Bell & Gossett brings 21st century
technology to residential controls.