Mechanical seal specifications
Materials of
Construction
BUNA carbon/ceramic EPR carbon/tungsten
carbide
EPR Sic/SiC Viton carbon/ceramic
Standard/optional Standard Optional Optional Optional
Operating
temperature range
-20˚F to 225˚F (-29˚C
to 107˚C)
-20˚F to 250˚F (-29˚C
to 121˚C)
0˚F to 250˚F (-18˚C to
121˚C)
-10˚F to 225˚F (-23˚C
to 107˚C)
pH range 7.0–9.0 7.0–11.0 7.0–12.0 7.0–9.0
Maximum glycol/
water concentration
50/50% 50/50% 60/40% 50/50%
Maximum suction
pressure
Suction Pressure + TDH must not exceed MWP
Product Description