Bell System (Telephones) Ltd.
BF Apartment Station Digital Entry System bellfree Apartment Station BFD-DIG controller BSC4 controller BSA audiophone BS videophone BS Deskphone PD–166 Issue 1 Installation and Operating Manual Page 2 of 48
BF Apartment Station Digital Entry System TABLE OF CONTENTS TABLE OF CONTENTS ...................................................................................................... 3 INTRODUCTION ................................................................................................................. 4 DESCRIPTION ..................................................................................................................... 4 MAIN FEATURES .....................................................
BF Apartment Station Digital Entry System Introduction Description A bellfree video door entry system consists of a door panel, positioned at the entrance of a building, apartment stations and other telephones, placed inside of the building for the convenience of the occupants and a power supply and controller which are usually located inside an electrical cupboard.
BF Apartment Station Digital Entry System bellfree Colour Apartment Station View Pickup Display Contrast Mute Lock Ringer Volume System Symbol Mute on/off Pickup / end View / camera select Lock PD–166 Issue 1 Lamp Red Steady Flashing Apartment station is muted Doorbell – All Flash Blue Call in progress Green Door is open Installation and Operating Manual Ringing Touch to release lock Page 5 of 48
BF Apartment Station Digital Entry System Basic System Operation Panel Controls Call Button Cancel Button Reception or Porter Button Door Button (Trades) Number and Letter Buttons The numbers 0 to 9 are used to enter numbers. The letter button >A enters letters beginning with A and each press advances through the alphabet, while the letter button
BF Apartment Station Digital Entry System The call may be terminated by touching the pickup symbol again or more usually by touching the lock symbol first to allow the visitor access through the entrance; the speech and picture will persist for a further 3 seconds while the door is being released.
BF Apartment Station Digital Entry System Cameras The door controller has the capability of using one or two cameras, for instance a second panel camera for DDA or a „third party‟ „CCTV‟ camera located to offer a different entrance viewpoint. Touching the view symbol will alternate the view between camera 1 and camera 2 (if enabled). Note. The camera to controller wiring has termination options which allow for connections to other video equipment. See the Camera sharing diagram on page 41 for details.
BF Apartment Station Digital Entry System Design Considerations Equipment List A bellfree digital video system comprises the following: Model No N x BF 1 x BFP-DIG/LCP -OR1 x BFP-DIG/VR(S) 1 x BFD-DIG M x BSC4 K x PS4 1 x 203 Description Colour Apartment station (N is the no of phones) Laser Cut panel with a BF-AMP speech unit, camera, VR buttons and LED display. Flush fitting only. Vandal resistant panel with a BF-AMP speech unit, camera, VR buttons and LED display. Flush or surface mounting.
BF Apartment Station Digital Entry System Video Controller The video controller(s) and power supply(ies) should be wall-mounted in a convenient cupboard or other protected environment with available mains power. Cable length to the apartment station should be less than 150m, see „Cable Distances‟ page 13. In many cases the video controllers will be in the same location as the door controller(s), but they may be distributed as required to reduce wiring distances.
BF Apartment Station Digital Entry System Exact power supply requirements depend upon many factors. The number of power supplies included within a standard „kit‟ or quotation assumes that all controllers are installed in one location and that there are no extensions. The following table gives examples of the minimum number of controllers and power supplies for a given number of entrance doors and flats.
BF Apartment Station Digital Entry System Cable Specification All system wiring must be carried out using Cat5 signal cable and where necessary 1mm² (or greater) power cable as tabulated below. Cat5 cable has a known performance for the transmission of video signals, whilst telephone or alarm cables are not suitable. Bell System will be unable to offer any warranty or support for systems installed using incorrect cables.
BF Apartment Station Digital Entry System Cable Distances Video Controller to BF Apartment Station System Distance Cable Comments Single apartment station < 150m 1 x Cat5 per output or first < 300m 1 x Cat5 apartment station 2 x 1mm2 Single apartment station < 50m 1 x Cat5 Only Master apartment station + 3 extensions on each has „Auto display‟; < 200m 1 x Cat5 2 output, all cable powered extensions are daisy-chained 2 x 1mm Single apartment station < 150m 1 x Cat5 150m maximum to the cable per output with s
BF Apartment Station Digital Entry System Installation & Commissioning Checklist The following checklist is a summary of what is required. Refer to the relevant pages for further details. ● Review the section headed „Safety Information‟ on page 47. ● Ensure that „Design Considerations‟ on page 9 have been understood. ● Confirm that Cat5 cable has been specified. ● Install the system according to instructions in this section. ● Check/set the door controller settings.
BF Apartment Station Digital Entry System Apartment Station The apartment station is designed to be surface or flush wall mounted onto plasterboard or other masonry at an optimum screen height of 1.6m. DDA considerations may reduce this height to 1.4m. Dimensions are shown in the diagrams below.
BF Apartment Station Digital Entry System BSA Audio Phone The BSA audio phone can be used as a lower cost alternative to an extension apartment station. It is styled like the bellissimo videophone. The phone is manufactured in high-impact ABS plastic that imparts high durability and compliments most wall furnishings. It incorporates both mute and lock illuminated buttons and it has an Electronic Ringing Tone with an internal rotary pre-set volume control.
BF Apartment Station Digital Entry System Electric Door Release Both fail-secure and fail-safe lock releases (including magnetic locks) use the same terminals. To set the lock type, refer to the „Door Controller Settings‟. When installing lock releases please allow a little movement on the door, as operation will be impaired if fitted too tight. NB. Magnetic locks (maglocks) must be fitted with a suppressor at the lock terminals. Some manufacturers fit an acceptable internal suppressor.
BF Apartment Station Digital Entry System Commissioning The major components of the bellfree Digital system are fitted with high quality pluggable screw terminal blocks. This enables all the connections to the system to be fully completed, whilst easily isolating individual pieces of equipment during testing and commissioning. When powering up for the first time, it is highly recommended that only the most basic system be connected. i.e.
BF Apartment Station Digital Entry System BFD-DIG Door Controller Settings The BFD-DIG is programmed from the panel for all settings. Security It is strongly recommended that the Panel Security Code (PSEC) be changed from its factory setting to prevent unauthorised access. Record the new number carefully as it cannot be easily changed if lost. It is also recommended that the Phone Programming Code (PPRG), Coded Access Code (ACOD) and Trades Access Code (TCOD) are all changed from default even if not used.
BF Apartment Station Digital Entry System ACOD – Primary Access Code Main code to open the door. Applies whenever the display indicates [Code]. The Trades mode (TRAD) needs to be set to „Code‟ or „Trade‟ as per the table below. The code must be 4 digits and no letters, leading 0 is OK (e.g. [0246]). TCOD – Secondary Access Code or Tradesmen’s Code Secondary „tradesmen‟s‟ code to open the door. Valid only when the display indicates [Code] and the time clock selects the Trade option as per the table below.
BF Apartment Station Digital Entry System PSEC – Panel Security Key The security key is required to gain access to panel programming. The code is entered then pressing the call button, the default is [3434] and it is recommended that this be changed for security. This code can contain letters and numbers for added security. PPRG – Phone Programming Security Key The phone programming security key is required to gain access to flat number programming of telephones.
BF Apartment Station Digital Entry System TONE – Re-assurance Tone To conform to DDA requirements the controller can provide a re-assurance tone at the door when an apartment station is being called and also when the door lock has been operated. The volume is adjustable from 0 using the volume control on the BFD-DIG controller PCB (see the diagram on page 34). In addition there is a choice of which tone is sounded. Four settings are available: [Both] = Ringing and lock tones. [Call] = Ringing tone only.
BF Apartment Station Digital Entry System BSC4 Video Controller Settings Jumper settings The “Video Gain” jumper on video controllers should always be set to “0” unless directed by Bell System Technical. This jumper is only required on some systems with very long camera to apartment station cable runs well in excess of 150m. Inappropriate use of this jumper with short runs will cause picture problems.
BF Apartment Station Digital Entry System Odd/Even Addressing Jumper PROG pins 1-2 This jumper alters the addressing of Phone outputs 2, 3 and 4 such that they all become either odd or even numbers. So if the address of output Phone 1 is 12 say the other outputs become 14, 16 and 18. If the address were 31 then the other outputs are 33, 35 and 37. The use of this jumper precludes the use of extended addressing by PROG pins 2-3, if both are required contact Bell System Technical.
BF Apartment Station Digital Entry System BF Apartment Station Switch Settings Mute Time Setting SW2 (1-4) 2 On On Off Off On On Off Off On On Off Off On On Off Off 3 On On On On Off Off Off Off On On On On Off Off Off Off 4 On On On On On On On On Off Off Off Off Off Off Off Off Mute Time Disabled¹ 2 minutes 5 minutes 10 minutes 15 minutes 20 minutes 30 minutes 45 minutes 1 hour 2 hours 4 hours 5 hours 6 hours 8 hours 10 hours *Indefinite² SW2 (QWERGHJK) 1 On Off On Off On Off On Off On Off On Off On
BF Apartment Station Digital Entry System BS Videophone Switch Settings Mute Time Setting SW2 (1-4) 2 On On Off Off On On Off Off On On Off Off On On Off Off 3 On On On On Off Off Off Off On On On On Off Off Off Off 4 On On On On On On On On Off Off Off Off Off Off Off Off SW2 Mute Time Disabled¹ 2 minutes 5 minutes 10 minutes 15 minutes 20 minutes 30 minutes 45 minutes 1 hour 2 hours 4 hours 5 hours 6 hours 8 hours 10 hours *Indefinite² (QWERGHJK) 1 On Off On Off On Off On Off On Off On Off On Off On
BF Apartment Station Digital Entry System Troubleshooting Common Faults A very high percentage of calls to our technical support number, regarding new installations, are resolved to faulty wiring. The reasons for these are various: Broken cores, especially short links, sometimes broken inside the insulation! Connectors clamped onto the insulation instead of copper. Wire in the wrong side of a rising clamp connection, the clamps need to be unscrewed far enough to stop the wire going “underneath”.
BF Apartment Station Digital Entry System Apartment station, Video or Audio Phone Call Problems Apartment station does not ring Apartment station off hook or muted. or flash when called. No power to apartment station; check that the mute lamp illuminates when the mute symbol is touched. Display indicates Fail. Data wiring has a fault, Data A or Data B connection broken. 0V to controller missing on separately powered apartment station.
BF Apartment Station Digital Entry System Lock Release Problems Lock release does not operate or clicks but does not open. Maglock does not hold strongly. TEST: Press „Test’ Button on Door Controller (when system idle): Lock release operates all the time or in reverse Lock operates from the exit button but not the test button or apartment station. Connections to Lock Release are open or shorted. Voltage drop due to cable too thin. Lock current is too high; Power supply is resetting.
BF Apartment Station Digital Entry System Specifications BFD-DIG Door Controller Size Supply Voltage Current Consumption 185mm x 230mm x 42mm 10.8V min, 13.8V typical, 15V max 80mA idle @13.8V, 500mA active Includes display, speech not cameras. Model C-CAMBS Colour Camera Size Supply Voltage Current consumption Image Device Sensitivity Minimum Focus Viewing Angle Video Output Resolution Back light compensation 60mm x 57mm x 31mm 10V d.c. minimum, 15V d.c.
BF Apartment Station Digital Entry System Model BSA Phone Size Supply Voltage Current consumption 235mm x 105mm x 25mm 10V d.c. minimum, 30V d.c. maximum 20mA idle, 67mA ringing @13.8V Model BF-AMP Speech Unit Size Supply Voltage Current consumption 95mm x 75mm x 30mm 10.5V d.c. minimum, 15V d.c. maximum 250mA d.c. maximum PS4 Power Supply Size Output Voltage (regulated) Output Current Mains Supply Internal Fuse Supply Voltage Temperature Range 236mm x 105mm x 81mm 13.5V d.c. min, 13.8V d.c. nom, 14.
BF Apartment Station Digital Entry System PD–166 Issue 1 Installation and Operating Manual Page 32 of 48
BF Apartment Station Digital Entry System Diagram A – Basic System Wiring Overview BF Apartment Station Up to 150m (1 Apartment station) 1 Cat5 per phone (For over 150m or extensions see diagrams H&I) BSC4 4 way Video Controller BSC4 4 way Video Controller Cat5 Further Controllers 2 x 1mm² Further Entrances Cat5 PSU PS4 12V Cat5 (For power supply requirements see table) Cat5 BFD-DIG Door Controller BFD-DIG Door Controller All cable MUST be Multiple Cat5 Cables Cat5 4 pair data cable.
BF Apartment Station Digital Entry System Diagram B – BFD_DIG PCB Detail Input Output Camera 1 Camera 2 Video Audio Data Commn Video Audio Data 28V + – M S + – M S + – 2 1 B A – – + – 2 1 B A – + 100 75 High Cam2 + – + – + – PM 12V SPKR Cam1 Audio Video Speech 43210 Video Gain Vol+ Vol– Save Speech Unit 100 75 High Cam2 HF Prog Panel Speaker 1 Panel Tone Volume Status bell Label BFD-DIG Version No Build No System © 2010 + – Time Test Prog-6 1 bellfree BFD-DIG Enhanced Speech Door Co
BF Apartment Station Digital Entry System Diagram D – Basic System Wiring Detail From previous controller W/Brn Brn W/Grn Grn W/Org Org W/Blu Blu W/Brn Brn W/Grn Grn W/Org Org W/Blu Blu To Next controller + – M S + – M S – + 2 1 B A – – – + 2 1 B A – – Camera 1 Camera 2 Video Audio Data Commn Video Audio Data 28V 12V Spkr Mic PM Speech Unit BD10 Display Module – + – + – + – 2 Panel Mic Entrance W/Blu Blu 12V 12V + – + – 2 x 1mm² – PS4 230V + Power Supply Mains 12V – + Blu W/Blu Org W/Org
BF Apartment Station Digital Entry System Diagram E – BSC4 PCB Detail Phone 1 Phone 2 Phone 3 Phone 4 28V Data Audio Video + – A B 1 2 + – 28V Data Audio Video + – A B 1 2 + – 28V Data Audio Video + – A B 1 2 + – 28V Data Audio Video + – A B 1 2 + – Test Phone 1 Power 1 Test Phone 2 Test Phone 3 Power 2 Power 3 Test Phone 4 Power 4 Test Audio on Select 1 Select 2 Select 3 Select 4 1 Status Prog Video Gain OFF ON 4 3 2 1 0 Label BSC4 Version No Build No Set Phone Address Video Audi
BF Apartment Station Digital Entry System Diagram F – BSC4 Wiring Detail 28V Data Audio Video + – A B 1 2 + – 28V Data Audio + – A B 1 2 28V Data Audio Video Bell + – A B 1 2 + – + – Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn BF Apartment Station Blu W/Blu Org W/Org Grn W/Grn BSA Audio Phone Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn BS Videophone Bell Push (non-illuminated) Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn – + 2
BF Apartment Station Digital Entry System Diagram G – Large system Overview Illustration of Power Supply Distribution Further Entrances Further Controllers 2 x 1mm² Detailed Wiring and Power Supply Calculations are in Manual Passthru Input BSC4... Controller x4 Monitors Cat5 Cat5 Door Panel BFDxxx Controller Output 2 x 1mm² Door Panel 2 x 1mm² Input Cat5 Input BFDxxx Controller Passthru Correct Video Operation Requires This Daisychain Wiring Input BSC4...
BF Apartment Station Digital Entry System Diagram H – Extension Apartment Station Wiring Master Extension Extension Extension 1 Cat 5 Plus Optional Power Cores When additional power cores are required replace the Blu and W/Blu wires with the additional wires 28V Data Audio Video Bell + – A B 1 2 + – + – 28V Data Audio + – A B 1 2 28V Data Audio Video Bell + – A B 1 2 + – + – Blu W/Blu Org W/Org Grn W/Grn Brn W/Brn BF Apartment Station Blu W/Blu Org W/Org Grn W/Grn BSA Audio Phone Blu W/Blu Org W
BF Apartment Station Digital Entry System Diagram I – Apartment Station Local Power Wiring Where more than one extension video unit is required to provide "auto display" then additional power supplies will be required Master Extension Extension Extension 1 Cat5 PSU 340C 12V PSU 340C 12V The 28V+ connection is only connected to the local power supply.
BF Apartment Station Digital Entry System Diagram J – Camera Sharing & Time Clock Sharing Camera Termination Options Cameras may be wired in either twisted pair or coax and shared with other equipment.
BF Apartment Station Digital Entry System Diagram K – Combined Connections bellfree With Lock Connecting a Bell PAX1 Proximity Reader – + Z Exit O OV H +12V C + – Lock PAX1 Proximity Reader – + Z Exit O OV H +12V C Exit button (Optional) Lock PAX1 Proximity Reader Exit button (Optional) Exit bellfree Door Controller – + 12V + – Exit bellfree Door Controller – + 12V Connect the lock release as per this manual.
BF Apartment Station Digital Entry System Diagram K – Continued Connecting a Bellcode Coded Access Controller Bellcode 200 Controller Lock Supply + – + – bellfree Door Controller Exit button (Optional) – Exit – Supply Connect the lock release as per this manual. Leave the Bellcode controller set to fail secure, the BFD controller sets the lock type. See "Bellcode Manual inc CK200 CS109 (PD-078)" for the other installation and setting instructions. Note 1.
BF Apartment Station Digital Entry System Diagram L – Combined Connections Third Party Lock Connecting a Bell PAX1 Proximity Reader Z Exit Z O Exit O + – Lock bellfree Door Controller – Supply PAX1 Proximity Reader Exit button (Optional) The bellfree door controller is set to fail secure. The diagram assumes a common power supply, if not an extra wire will be required to connect the PAX1 Exit O to the bellfree 12V-. N.B.
BF Apartment Station Digital Entry System Diagram L – Continued Connecting a Bellcode Coded Access Controller bellfree Lock + – Exit – Door Controller + – Exit Bellcode 200 Controller The bellfree door controller is set to fail secure. The Exit- to Exit- wire is only needed if the two units do not share a common power supply. Opening a Gate or Locks on Third Party Systems bellfree Door Controller + Lock – Coil Coil Com 89 Relay NO NC Volt Free Contacts For Gate ETC.
BF Apartment Station Digital Entry System PD–166 Issue 1 Installation and Operating Manual Page 46 of 48
BF Apartment Station Digital Entry System Safety Information and Declarations Connections to the 240VAC mains supply must be carried out by a qualified electrician or similar competent person, and made in accordance with current legislative requirements. A two-pole switch (as provided by a Consumer Unit or Switch-Fuse) must be included to isolate both Live and Neutral during Installation or Maintenance.
BF Apartment Station Digital Entry System Bell System (Telephones) Ltd. Presley Way, Crown Hill, Milton Keynes MK8 0ET. Tel: 01908 261106 (Sales and Technical Support) FAX: 01908 261116 OR Local rate numbers Tel: 0845 121 4008 (Sales and Technical Support) FAX: 0845 121 4009 E-mail: sales@bellsystem.co.uk technical@bellsystem.co.uk Website: www.bellsystem.co.uk Standards This product complies with European directive 89/336/EEC on Electromagnetic Compatibility and Low Voltage Directive 72/23/EEC.