User's Manual

BSX Isolated Audio Entry System
PD-142 Issue 1 Installation and Operating Manual Page 16 of 32
The TS2000-BST Time-Clock Module
This section describes the operation and programming of the TS2000 Time Clock module
for use with the Tradesman’s facility.
CAUTION
The unit is intended for 12V AC / DC operation only, and must not be connected to the
Mains supply or used to switch Mains voltages.
Operation
N.B. Before programming or setting the clock for the 1st time press the Reset button.
Programming may be carried out without 12V power applied, but all other operations,
Override etc. need the Green Power LED to be lit. Also loss of 12V power may affect any
override actions set by either the On/Auto/Off or Override buttons, but not any timer events
even if they occur while power is removed.
To set the current TIME and DAY
1. Hold ‘Clock’ and press ‘Year’ until the correct year is displayed.
2. Hold ‘Clock’ and press ‘Month’ until the correct month is displayed.
3. Hold ‘Clock’ and press ‘Day’ until the correct day is displayed.
4. Hold ‘Clock’ and press ‘Hour’ until the correct hour is displayed.
5. Hold ‘Clock’ and press ‘Min’ until the correct minutes are displayed.
To set the programs
1. Press once, 1on will appear. This displays the switch on time of the 1st
program.
2. Press ‘Day’ to select the program period. There are 15 settings:
1. Mo+Tu+We+Th+Fr+Sa+Su Mo+We+Fr
2. Mo, Tu, We, Th, Fr, Sa, or Su Tu+Th+Sa
3. Mo+Tu+We+Th+Fr Mo+Tu+We
4. Sa+Su Th+Fr+Sa
5. Mo+Tu+We+Th+Fr+Sa
3. Press ‘Hour’ to select the hour.
4. Press ‘Min’ to select the minutes.
5. Press once, 1off will appear. This displays the switch off time of the 1st
program.
6. Repeat steps 2,3 and 4 to set the off day and time.
7. Repeat steps 1 to 6 to set the 2nd, and remaining programs, as necessary.
ON
AUTO
OFF
OVERRIDE
ONON
C
L
O
C
K
Y
E
A
R
M
I
N
T
I
M
E
R
Switch Status
Clock/
Set Clock
Timer Status Bar
Override Status
Power Status
Program Mode
Manual Override
Reset Button
Current DateSummer Time lndicator
Program