Specifications

18
If in [Command Mode , Page 5] Keycode has been activated, the displays will show:
Quit Standby Mode by eliminating the problem (for example short circuit at output) or by
entering the correct keycode.
Now the window to deactivate Power Control and Sine TEST will open.
If Power Control is deactivated in this new window, Stand by Mode will be inactive
after Mains off / on - even if the original problem (short circuit at speaker output) has not
been eliminated.
When Sine Wave Test is activated, Power Control should not be deactivated!
If in [Command Mode, Page 5] the Keycode function has not been activated, the LCD
Displays will show the information as under B.
4) Should the input level of CH.A or CH.B have a damping below 30dB,
[View Mode , Page 1] the Auto Fade In function will now be activated. This feature will
softly fade in the output level of the power amplifier in order to avoid any harsh or
unexpected loudspeaker signals.
5) In conjunction with the Command switch, the displays will now show the functions
of the Command- or View mode.
View Mode
This function is activated by pushing the Command switch (green LED off)
when View Mode has been activated. Select the next page by operating the page / exit
key.
Page 1
A
B