Installation Guide

19
Pic. 4.4 Pic. 4.5
When using two internal trims, you must cut the panels 1¼” shorter than the wall to wall measurements
using left to right measurements. Slide the panel all the way into the left channel and then position the
right side at the channel and slide it in about half-way in keeping the left side in the channel as well.
Dry fit the wall opposite valve wall to make sure it fits by the top of the panel meeting the line on the
wall and the outside line on wall for the edge of the panel. Check the leg to make sure it has a snug fit
to the Tub/Pan (if using a tub leg). Make sure that the tub spout hole and valve hole line up properly
(pic. 4.5).
o Apply silicone to the Internal Trim channel as well as to valve wall but make sure to hold the
silicone 1½” short of outside edge line on wall for the trims to slot in later.
o Install panel
Pic. 4.6
Dry fit the Valve Wall to make sure it fits the top of the panel meeting the line on the wall as well as
outside line on wall for the edge of the panel (pic. 4.6).
o Apply silicone to the Internal Trim channel as well as to valve wall but make sure to hold the
silicone 1½” short of outside edge line on wall for the trims to slot in later.