Step 3
PROG
Central unit SCU
Any error during programming is signaled with [ ]. The procedure must be repeated from Step 2.
BEEEEP
Press PROG. The red LED turns off.
BEEEEP
Long press of [ ]. The panel goes in programming.
BEEP
- For panel address 1 - 1 short touch of 1 x [ ] Step 3.
BEEP
- For panel address 2 - 2 short touches of 2 x [ ] Step 3.
BEEP
- For panel address 3 - 3 short touches of 3 x [ ] Step 3.
BEEP
- For panel address 4 - 4 short touches of 4 x [ ] Step 3.
ACCESS with TAG
(RFID access)
The symbol indicates the RFID tag reading area. The tags are
already memorized. When used, the locks opens, the panel emits
a sequence of beeps for confirmation and the symbol blinks green.
Only for Outdoor panel with RFID
6.4.2 Programming the panel address
The panel is already programmed with address 1, which is mandatory for the correct
functioning of the system. The programming is necessary only if:
- The address 1 is changed by mistake during installation.
- Additional panels are installed. The system allows up to 3 additional panels (each with a SCU)
and each of them must be programmed from its own SCU with a different address 2, 3 or 4.
Step 1
Central unit SCU
PROG
Outdoor panel
VPA
Step 2
Long press of PROG. The red LED turns on.
Any error during programming is signaled with [ ] . The procedure must be repeated from Step 2.
BEEEEP
6.4.3 Programming additional access tags (panel with RFID only)
Step 1
Central unit SCU
PROG
Touch with the tags, piece by piece, the symbol.
BEEEEP
After each memorized tag [ ].
Outdoor panel
VPA
Step 2
Step 3
PROG
Central unit SCU
Long press of PROG. The red LED turns on.
Press PROG. The red LED turns off.
Step 3
Step 1
Step 2
6.4.4 Deleting all the programmed tags (panel with RFID only)
Use this procedure only if you lost one or more of your tags. The remaining ones must be programmed again.
Central unit SCU
Central unit SCU
Outdoor panel
VPA
Press PROG. The red LED turns off.
Long press of PROG. The red LED turns on.
Long press of [ ] . The Panel goes in programming.
BEEEEP
- 7 short touches of 2 x [ ].
BEEP
- Immediately one long press of ].The tags are deleted.
BEEEEP
[
Name 2
Name 1
Name 3
PROG
PROG
Name 2
Name 1
Name 3