User manual

Name 2
33
6.4. Use of the outdoor panel (VPA)
IR LEDs (night lighting)
o
25 Adjustable Video camera
Residents’ names
Call key (touch)
RFID reader (only for RFID series)
Red LED (signaling the possibility of video
monitoring)
STAND-BY
The call keys and the residents` names are permanently backlit.
The RED LED is blinking.
CALL
Short touch of Acoustical signaling with a ding-dong.
Each touch of the key reactivates the call.
END CALL
After 1 min. since the last call.
TALK
The resident answers Hands-free conversation, without touching
any key. The talk duration is max. 2 min.
ACCESS being granted
The lock is open for the set temporization on SCU (between 1 and
10 sec.). The panel emits a sequence of beeps for confirmation.
Microphone
Loudspeaker
TORX Fixing screw
+
-
( )
TORX Fixing screw
! It must be screwed completely
- Antitheft alarm protection
Long press
RED
GREEN GREEN
Programming mode
(The kit is already programmed.)
BUTTON
PROG
LED
PROG
LED
S1
LED
S2
LED
S3
The system is not connected to the 230 Va.c./
50 Hz network.
The system is OK, connected to the 230 Va.c./
50 Hz network.
Significance of LEDs signaling on SCU
GREEN GREEN
The system is not connected to the 230 Va.c./
50 Hz network. The battery is functional.
The system works only on audio and door
opening, for a limited time slot.
GREEN
GREEN
The system is OK, connected to the 230 Va.c./
50 Hz network. The battery is functional.
When a battery is connected to SCU, there are the following additional signals only for S3 LED:
GREEN
GREEN
RED
The system is OK, connected to the 230 Va.c./
50 Hz network. Battery charging or defect.
6.4.1 Functioning
For LEDs signaling RED, see ch. 7 – Troubleshooting.
Name 3
Name 1