OTHER VIDEO CAMERA DOOR LOCKS OUT1 OUT1 OUT1 OUT1 N L SCU.VDR02.BLG14 OUT1 N L PSU.VDR02.BLG04 OUT1 SWC1 SWC2 Lc1 LC2 LA1 LA2 LS1 LS2 SCU.VDR02.xxy34 SCU.VDR02.BLG34 SCU.VDR02.xxy14 +U C/D GND Vout3 +U C/D GND Vout2 +U C/D GND Vout1 +U C/D GND Vin1 N L PSU.VDR02.
0 EN EN 1 1 2 3 4 5 6 7 Contents Safety instructions Description of the central supply and command unit (SCU) Functions of the central supply and command unit (SCU) Description and functions of the power supply unit (PSU) Recommended cables. Installation. Setting the programming mode for the Touch Line video door phone system Warranty 1 EN Safety instructions 1.
2 EN Description of the central supply and command unit (SCU) NOTE: For the video door phone systems with 1 Family and the systems with more than 3 Families, the central supply unit with 1 OUTPUT - SCU.VDR02.xxG14 will be used, which has only output OUT1 for Family 1 or a connection box. The central supply unit with 3 OUTPUTS - SCU.VDR02.xxG34 will be used for the video door phone systems with 2 and 3 families, being fitted with two more outputs – OUT2 and OUT3.
2.1 EN Electrical and mechanical features Power supply voltage: 110/ 230 Va.c. - 50/ 60 Hz Output voltage: 13.5 Vd.c. +/- 5% max. 2Ad.c. Overload protection for the input and output current Network overvoltage protection EMI filter (electromagnetic compatibility) Dimensions: (L) 130 x (l) 141 x (h) 73 mm Weight: 0.4 Kg Case: PA6.6 + FS 10% (fireproof) UL certified printed circuit board Operating temperature range: 0o – 40o C IMPORTANT: SCU.VDR02.
12. Additional devices (open auto gate, garage door, outdoor lights etc.) connected to the AUX1, AUX2 terminals. The relay issues a one second impulse (the AUX relay closes the contact for one second). 13. Rechargeable battery (12 Vc.c./ max. 7 Ah) connected to the +BAT, -BAT terminals for the installation to function in case of failure. 14. EXIT button, reclosing, connected to the SWC1, SWC2 terminals, for opening the lock when exiting the lobby of the building. B.
4 EN Description and functions of the power supply unit (PSU) IMPORTANT: The PSU.VDR02.xxG04 power supply unit is used in the Touch Line video door phone systems, when the +U power voltage measured at the last terminal (apartment) drops below 12 Vd.c., due to the high power intake of the video terminals. The PSU.VDR02.xxG04 supply unit is connected at the middle or at the end of the installation.
5 EN Recommended cables. Installation. 1. The central/power supply units will be installed in electrical cabinets specially built inside the building. They can be mounted on 46277-3, EN50022, IEC60715 DIN rail or directly with 2 M 3x12 screws, on the inside wall of the cabinet. 2. ATTENTION! For mounting, operation and service/maintenance, it is mandatory to comply with the SAFETY INSTRUCTIONS presented in Ch. 1 of this user manual. 3.
5.1 EN Connection of the panel and the terminals to the central unit (SCU) NOTE: The below diagram presents the configuration for a video door phone system with 3 Families, with a central unit with 3 OUTPUTS – SCU.VDR02.xxG34. 2. The central unit with 1 OUTPUT – SCU.VDR02.xxG14 is connected identically, lacking only the connections for OUT2 and OUT3. 3.
5.2 EN Connection of the alternating current lock at the central unit (SCU) LCK max. 24Va.c./5Aa.c. LCK max. 24 Va.c. 50Hz/60Hz 110Va.c./230Va.c. 50Hz/60Hz max. 24 Va.c. 50Hz/60Hz N L FROM THE OUTDOOR PANEL 5.3 EN DOOR LOCKS SWC1 SWC2 LC1 LC2 LA1 LA2 LS1 LS2 +U C/D GND Vin1 VIDEO DOOR PANEL 110Va.c./230Va.c. 50Hz/60Hz 2x6Aa.c. N L EN 8 Connection of the LS electromagnetic lock at the central unit (SCU) Electromagnet max. 24Vc.c./3Ac.c. 110Va.c./230Va.c. 50Hz/60Hz max. 24 Vc.c. max.
5.5 EN Connection diagram of the power supply unit (PSU) in the video door phone systems from buildings with multiple families IMPORTANT: The PSU.VDR02.xxG04 power supply unit is used in the Touch Line video door phone systems, when the +U power voltage measured at the last terminal (apartment) drops below 12 Vd.c., due to the high power intake of the video terminals. The PSU.VDR02.xxG04 supply unit is connected at the middle or at the end of the installation.
6 EN Setting the programming mode for the Touch Line video door phone system IMPORTANT: The programming mode is set from the SCU, by long pressing (2-3 sec.) the PROG. button PROG. button The PROG Red LED turns on and remains on during the entire programming phase. You can program: 1) The address of the terminal (apartment number) from 0002 to 9999.
ELECTRA Building Communications GmbH Bischoffgasse 5/3-4, 1120 Wien - AT +43 1 810 20 99 support@bellcome.com www.bellcome.com ELECTRA s.r.l Bd. Chimiei nr.8,Iași - 700291 - RO www.electra.ro BELLCOME is a trademark of ELECTRA Group - No. 013502646 EUIPO - Alicante, Spain BELLCOME is a trademark of ELECTRA Group - No. 1732510 MPI - Ciudad de Mexico, Mexico ELECTRA is a trademark of ELECTRA Group - No.