User manual

Description of the central supply and command unit (SCU)
2
EN
OUT3
ANOTHER VIDEO CAMERA
C/D
+U
GND
Vin2
AUX1
AUX2
+BAT
-BAT
+U
C/D
GND
Vout1
+U
C/D
GND
Vout2
+U
C/D
GND
Vout3
+U
C/D
GND
Vin1
SWC1
SWC2
Lc1
LC2
LA1
LA2
LS1
LS2
N L
VIDEO DOOR PANEL
DOOR LOCKS
Analog, PAL, CMOS/ CCD, 1 Vp.p.
with adapting video transformer
AUX1,AUX2
Connection of additional
installations:
auto gate, garage,
outdoor lights etc. (relay contact)
+BAT, -BAT
Connection of 12Vc.c.,
max. 7Ah rechargeable
battery
OUT1
Connection of cable to
the Fam. 1 terminal
or VCB
OUT2
Connection of cable to
the Fam. 2 terminal
or VCB
Connection of cable to the
Fam. 3 terminal or VCB
JP1 Disconnected Jumper
for connecting the Vcam
at the system
JP2 Connected jumper
for recording Vcam
images on DVR
FUSE, Electrical
network fuse 1.6 Aa.c.
LS1,LS2 Connection of electromagnetic lock
max. 3A/24 Vd.c.
LA1,LA2 Connection of
alternating current
lock max. 5A/ 24 Va.c.
LC1,LC2 Connection of
direct current lock
max. 0.8A/ 24 Vd.c.
SWC1,SWC2
Connection of
exit button
L,N, Connection to the 110/
230 Va.c. - 50/ 60 Hz network
VIDEO DOOR PANEL,
Connection of the cable
from the outdoor panel
PROG Programming mode
setting/resetting
button
LED PROG Red, the
panels and terminals are
in programming mode
TIME Lock
opening time adjustment
(max. 10s)
LED Green, presence of
110/ 230 Va.c. 50/ 60 Hz voltage
LED BAT Green, max. 7Ah 12V
rechargeable battery, connected
to the SCU
LED +U Green, +13.5 Vd.c. +/-5%
voltage presence
EN
2
NOTE: For the video door phone systems with 1 Family and the systems with more than 3 Families, the central supply unit
with 1 OUTPUT - SCU.VDR02.xxG14 will be used, which has only output OUT1 for Family 1 or a connection box.
The central supply unit with 3 OUTPUTS - SCU.VDR02.xxG34 will be used for the video door phone systems with 2 and 3
families, being fitted with two more outputs – OUT2 and OUT3. The two central units have similar functions.
SCU.VDR02.BLG34