User manual
Recommended cables. Installation.
5
EN
1. The central/power supply units will be installed in electrical cabinets specially built inside the building. They can be mounted on
46277-3, EN50022, IEC60715 DIN rail or directly with 2 M 3x12 screws, on the inside wall of the cabinet.
2. ATTENTION! For mounting, operation and service/maintenance, it is mandatory to comply with the SAFETY INSTRUCTIONS presented
in Ch. 1 of this user manual.
3. To connect the SCU central/ PSU power supply unit (L, N, ) to the 110 V/ 230 V – 50 Hz /60 Hz power network, it is mandatory
to use a H05VV-F4G 0.75 cable and two 6A automatic fuses.
Depending on the maximum distance between the outdoor panel and the last video terminal, the recommended cables at
installation are the following:
2
Option 1) 4 wires x 0.5 mm (type H03VV-F4G 0.5) for maximum 75 lm
2
Option 2) 4 wires x 0.75 mm (type H05VV-F4G 0.75) for maximum 150 lm
Connections to the
Outdoor panel
+U
C/D
GND
+U
C/D
GND
UTP cat5e (AWG24)
UTP cat6e (AWG23)
25-30mm
6mm
VinVout
6mm
25-30mm
Connections to the
Central Unit
SCU
+U
C/D
GND
Vin
+U
C/D
6mm
25-30mm
GND
Vout
6mm
25-30mm
1.Connections to
the Central Unit
2. Connections
to the Terminals
1.Connections to
the Outdoor panel
2.Connections
from the
Central Unit
to the Terminals
Beispiel: + U = Rot, C / D = Blau, GND = Schwarz,
Vin / Vout = Grün.
*Important: Maintain the same colors for the
same connections. Out of electrical security
reasons, we recommend installing a grounding
cable between the panel and the SCU.
Option 3) UTP cat5e (AWG24) maximum 250 lm. The wires will be arranged as per the below model:
EN
6