User manual
KIT INSTALLATION. Follow the steps below, in the described order.
STEP 1. Read the diagrams in this brochure and the technical manuals of the KIT (VPA, VTx, SCU).
STEP 2. Make the electrical connections to the terminals (ATM, VTM, VTA) and then to the VPA outdoor panel.
STEP 3. Make the electrical connections of the LC, LA or LS lock to the terminals of the SCU central supply and command unit
and, if necessary, the connections to: the EXIT button; AUX additional installations; BAT; Vcam analog video camera.
STEP 4. AUTHORIZED PERSONNEL!!! READ THE SAFETY INSTRUCTIONS FROM THE MANUAL OF THE SCU CENTRAL
SUPPLY UNIT!!! DISCONNECT the fuses and make the L,N, connections to the SCU CONNECT the fuses to the
power network. The , S2 LEDs turn on, and S1 turns on only if the battery (12V/7Ah) is connected.
STEP 5.1. PROGRAMMING THE MAIN ENTRANCE PANEL: RFID CARDS/TAGs At the SCU, long press (2-3 sec.) the PROG
button (point 5). The PROG Red LED turns on Go to the VPA panel from the main entrance and touch each RFID CARD
to the (RFID) area for one second. For each programmed RFID CARD/TAG, the panel issues two beeps.
Follow the same steps for programming all the RFID CARDS/TAGs, for all the residents of the building.
Return to the SCU and short press the PROG button. The Red LED turns off. The main panel keeps address 1, which
is set from the factory and is ready to function.
STEP 5.2. PROGRAMMING THE ADDITIONAL PANEL: NEW ADDRESS and RFID CARDS/TAGs. If the access in the building
is made through two entrances, the VPA2 additional panel (point 10) from entrance 2 must be set up with address 2.
At SCU 2 long press the PROG button. The PROG Red LED turns on. At the VPA2 panel, long touch the Fam.1 key, then
short touch the Fam.1 key, twice. The panel confirms the storage of address 2 with two short beeps. Continue programming
the CARDS/TAGs in the VPA2 panel. Each touch of the CARD/TAG to the area is confirmed by the VPA2 with two beeps.
Return to the SCU2 and short press the PROG button. The Red LED turns off. The VPA2 and VPA1 panels are ready to
function, with all the terminals in the building.
STEP 6.1 PROGRAMMING THE ADDRESS OF THE Fam.1 TERMINAL. The terminals keep Address 1, which is set by the
manufacturer.
STEP 6.2 PROGRAMMING THE ADDRESS OF THE Fam.2, Fam.3 or more TERMINALS. The terminals for Family 2 will have
address 2, the terminals for Family 3 will have address 3 and so on for 4, 5 etc.
Program the new addresses as follows: At SCU 1 long press (2-3 sec.) the PROG button. The PROG Red LED turns on
At the terminals for Family 2, long touch the key. The terminal confirms with one long beep. Short touch the
key twice. Two short beeps are issued. The terminal stores address 2. Continue programming address 3 at Family 3 following
the same steps. Long touch the key and after the long beep, short touch the key three times. Storage is confirmed
with three short beeps. The terminals are ready to function.
RECOMMENDED CABLES (point 1) Maintain the same wire colors for the same connections.
Out of electrical safety reasons, we recommend installing a grounding cable (minimum 1.00 mm – Green/Yellow) from the
panel (VPM) to the central unit (SCU).
1
DETAILED PRODUCT CODES
VPA - advanced video outdoor panel; Product codes: Video 1Fam.VPA.1S(F)R02.xxy04; 2Fam.VPA.2S(F)R02.xxy04;
3Fam.VPA.3S(F)R02.xxy04; 5Fam.VPA.5S(F)R02.xxy04 (S= Surface mounting, F= Flush mounting, R= RFID CARD/TAG access)
RFID access CARD/TAG (secured at reading and copying). They are stored and can be deleted from the VPM.
ATM - smart+ audio terminal; Product code: ATM.0S402.xxy04
VTM - smart+ 3.5” video terminal; Product code: VTM.3S402.xxy04
VTM/VTA - smart+/advanced 7” video terminal; Product codes: VTM.7S402.xxy04/ VTA.7S902.xxy04
VCB – Video connection box (1 video input/4 video outputs - 4 Fam.); Product code: VCB.4DN02.xxy04
EN
INSTALLATION INSTRUCTIONS – VIDEO DOOR PHONE KIT
Thank you for choosing the BELLCOME products. We will assist you throughout the entire warranty period.
For technical support and assistance you can contact us at ELECTRA Building Communications GmbH +43 1 810 20 99,
support@bellcome.com.
2
1) Max. 75 ml 4 x 0.5 mm (H03VV-F4G 0.5)
2
2) Max. 150 ml 4 x 0.75 mm (H05VV-F4G 0.75)
3) Max. 250 ml UTP cat5e (AWG24) or UTP cat6e (AWG23)