User manual

EN
8
TIME and DATE setting for the advanced terminal
6.2
Touch the key and enter the Menu.
Continue to touch the key until you reach the Time & Date.
Scroll using the keys and touch to select the Time or the Date.
Adjust the parameters using the keys and touch the key
for the correct setting. Select Exit to exit the Time & Date menu.
ok
ok
ok
3
CALL RINGTONE VOLUME Successively touch the key, until you reach the desired
volume of the ringtone. Each volume level, from 1 to 7, is signaled by an increase in the
intensity of the selected ringtone.
The last played version remains stored for the call.
4
The settings mode will automatically close after 7 sec. from the last action.
2
CALL DURATION The terminal rings only once. Touch the key again.
The terminal rings twice. Touch the key for the second time.
The terminal rings three times. Touch the key for the third time.
The terminal rings continuously for 1 minute. Touch the key for the fourth time.
The last played version remains stored for call.
Programming the audio-video terminals
The manual programming of the address of the terminal (apartment number/ family)
All Touch Line terminals are programmed from the factory with address 1.
The terminals from apartments with numbers from 2 to 9999 will be programmed with
the number (address) of the respective apartment / family.
The address of the terminals with numbers from 2 to 20 can be manually programmed,
according to the following procedure:
0. The entire door phone system is installed and set under tension.
1. Go to the place where the SCU central unit of the installation is mounted. Long press
(2-3 sec.) the PROG button. The red LED turns on.
2. Return to the terminal and long touch the key. You will hear a long beep.
- Programming address 1: touch the key once. A short beep is issued.
- Programming address 2: touch the key twice. Two short beeps are issued.
- Programming address 3: touch the key three times. Three short beeps are issued.
Repeat the procedure for the next addresses, until 20.
NOTE: After pressing the key n times, wait a few seconds for the acoustic confirmation
of the terminal for address n. The terminal will issue n beeps for address n programmed
in the terminal.
3. Return to the SCU central unit of the installation. Press the PROG button for a short time.
The red LED turns off. The installation returns to normal functioning mode.
For programming the Touch Line terminals installed in buildings with a high number
of apartments (higher than 15), purchase the special terminal address programming
device from the producer.
7
EN
ok