Service manual
Connect to the electricity supply
Warning: This appliance must be
earthed.
The appliance must be installed by a
competent electrician using a double
pole control unit of 32 ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance
is connected by a competent person
who is a member of a recoqnised
'competent persons scheme' and who
will comply with local regulations.
1. Access to the mains terminal is
gained by opening the terminal
block cover at the rear of the
appliance (use a small flat-bladed
screwdriver).
2. Connection should be made with
6.0mm
2
flexible twin and earth
cable.
3. First strip the wires, then push the
cable through the cable clamp in
the terminal block cover.
4. Connect the cable to the terminal
block using an 8mm socket and
tighten the cable clamp screw (see
diagram).
5. Close the terminal box, ensuring
that the cover is engaged on the
locking tabs.
6. Sufficient cable should be use to
allow the cooker to be pulled out,
but must hang clear of the floor so
it does not become twisted or
trapped when the cooker is pushed
back.
46
L
N
Cable Clamp
INSTALLATION INSTRUCTIONS