Technical data
installation
Makesurethattheexible
connector does not block the cooling
fan inlet.
4. Flexible connections should comply
with BS 669.
Parts of the appliance likely to come into
contactwithaexibleconnectorhavea
temperature rise of less than 70°C.
5. Rigid connections must be accessible
to disconnect for servicing.
Cut a 150mm square hole in the right
hand rear corner of the support shelf for
the supply pipe.
6. Make sure all connections are gas
sound.
Step 3 : Connect to the electricity
supply
Warning: This appliance must be
earthed.
Theexiblemainsleadissuppliedcon-
nected to a BS 1363 fused plug, the plug
isttedwiththecorrectfuse.
Replace only with a fuse of the same rat-
ing and type.
The wires in the mains lead are coloured
inaccordancewiththefollowingcode:
Green and yellow = Earth,
Blue = Neutral,
Brown = Live.
As the colours of the wires in the mains
lead for the appliance may not correspond
with the coloured markings identifying the
terminalsinyourplug,proceedasfollows:
1. The wire which is coloured green and
yellow must be connected to the terminal
markedE(Earth)orcolouredGreen.
2. The wire which is coloured blue must
be connected to the terminal marked N
(Neutral),orcolouredBlack.
3. The wire which is coloured brown must
be connected to the terminal marked L
(Live),orcolouredRed.
The plug and socket must be accessible
after installation. Should the mains lead of
the appliance ever require replacing, this
mustbecarriedoutbyaqualiedelectri-
cian who will replace it with a lead of the
same size and temperature rating.
Important:-ensurethatyourouteall
mainsandelectricalcablesandexible
tubing well clear of any adjacent heat
source.
Under no circumstances should the mains
electric cable be allowed to come into
contactwiththeverticalovenuetubes
on the rear of the appliance.
E (Earth)
Green/Yellow
N (Neutral)
Blue
L (Live)
Brown