User's Manual

Quick start guide
Make sure to select a location complying with the advice in Location and positioning.
1 Lift o the mounting bracket and carefully place your thumb over the batteries and
remove the pull tab to power the smoke alarm.
2 Taking care to avoid any electrical wiring, x the mounting bracket to the ceiling or
wall using the supplied screws and plugs. Mount it at least 305 mm (12") from walls
and obstructions, ideally centrally in the room or area.
3 Fit the alarm to the bracket by turning it clockwise until it snaps into place.
Testing the connection
1 Press the test/silence button and release
it when the alarm sounds. The alarm
transmits a radio signal to the receiver.
2 The red Visit LED on the receiver lights up
to show that the signal was received. In
addition, it starts to sound, ash or vibrate
depending on the receiver.
Note: The alarm will stop sounding after the
button is released and the Visit receiver will
time out in less than a minute.
PULL THIS TAB
1
1 2
32
3 4
Indication summary
Normal operation Action LED Sounder
Power up Pull battery tab 1 red + 1 yellow blink O
Standby O O
Sensing re Red + green Full sound
Silence alarm Press test button 1 red blink / 8 s O for 10 mins
Fault mode Action Alarm LED Sounder
Low battery 1 yellow blink / 48 s 1 beep / 48 s
Faulty smoke sensor 2 yellow blinks / 48 s 2 beeps / 48 s
Faulty heat sensor 2 yellow blinks / 48 s 2 beeps / 48 s
End of life 3 yellow blinks / 48 s 3 beeps / 48 s
Silence end of life
for up to 30 days
Press test button O for 72 h O for 72 h
Contaminated
chamber
4 yellow blinks / 48 s O
Test mode Action Alarm LED Sounder
Test smoke alarm Press test button Red + green Full sound
Alarm memory Action Alarm LED Sounder
24 h memory* 2 red blinks / 48 s
for 24 hours
O
Memory reset* Press & hold button Rapid red blinking Rapid chirping
Note: During test and in case of re, the red LED on the Visit receiver lights up and it
starts to sound, ash or vibrate depending on the receiver.
* See Alarm memory on page 25.