- Belshaw Bros. Operator's Manual Fill and Filter EZ18, EZ24, EZ34

Filtering
1. Turn the fryer off. Allow the shortening to
cool to 130 F/54 C.
WARNING
Hot shortening may cause serious injury.
2. Turn the EZ Melt off. Make sure that both
the HEAT and PUMP switches are in the
OFF position.
3. Make sure that the top of the cube melter is
exposed.
Figure 2-6. When to Drain the Fryer.
Figure 2-6A.
(EZ-34 ONLY) When to Drain
the Fryer.
WARNING
When you begin to drain the fryer, the
shortening in the EZ Melt must be shallow
enough for the top of the cube melter to be
exposed. If the shortening is deeper it might
overflow when you drain the fryer, thus
causing burns or other serious injury.
4. Position the shortening filter assembly on
the EZ Melt kettle. The edge of the kettle
has one or two sets of holes in it. Use the
set of holes that is farther from the heater
head. When two of the filter frame’s pins
rest in these holes, the filter assembly rests
horizontally on the end of the kettle. (See
Figure 2-7.)
Figure 2-7. Positioning the Filter Assembly
for Filtering.
5. Disconnect the supply hose from the hose
connector. Hold the two ends of the hose up
so shortening does not drip out. Hang hose
vertically over a pan so the shortening will
drip into the pan.
6. Attach the rinsing hose securely to the hose
connector. (See Figure 2-8.)
If
shortening
level is
here or
below
drain fryer.
Side of
Cube
Melter.
Bottom of
kettle.
If
shortening
level is here
or below
drain fryer.
Side of
cube
melter.
Bottom of
kettle.
Belshaw Bros., Inc. 1750 22
nd
Ave. S. Seattle, WA 98144 Phone 206-322-5474 Fax 206-322-
5425
EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN 7