Operator`s manual

Belshaw Bros., Inc. www.belshaw.com Phone 206-322-5474 Fax 206-322-5425
10 MN-1718EN Thermoglaze 50 TS
Calibration Procedure for Temperature and Cook Time on
the Thermoglaze Model TG50
Turn off power to the TG50 before removing any
access covers. This procedure should be
performed only by qualified service technicians.
Remove the electrical box cover on the oven to
access the temperature and speed control
adjustment potentiometers. The following is a
photo of the location of the adjustment
potentiometers for the temperature and cooking
time for the Belshaw TG50 Thermoglaze.
Rocker Switches
Temperature Controller
Speed Controller
Conveyor drive motor
Transformer
Terminal Block
Power Distribution Block
SSR Relays
VFD
Circuit Breakers
Timer
MCR
Heater Contactor
Glaze Pump
Safety Switch