Technical data
Page 12
INSTALLATION
TYPICAL PIPEWORK ARRANGEMENT
SOLAR PANEL TYPICAL CONNECTION DIAGRAM TO BOILERMATE SP SOL
Figure 1.10
Solar overheat sensor T3
Collector
sensor T1
Roof Pitch
Solar Panel
Flow Meter
and Regulator
0.5 - 13 l/m
Internal Ceiling
1 bar
82 C
o
Solar Controller
Sensor Cable
Junction Box
Solar Return
Sensor T2
13
1
l /min
FILL CONNECTION
DRAIN CONNECTION
OV /
Safety
CF /
Expansion
Expansion
Vessel
PRV
0
20 100
120
40 80
60
0
2 10
4 8
6
Temperature
Gauge and
Check Valve
This component
arrangement is
provided with the
SOL appliance and
must be mounted
vertically on the
connection
provided.
No isolation valve should
be installed between the
solar circuit and the safety
valve (pressure reducing
valve).
Note:
No valves should be fitted
on the pipework between
the solar collector and
the Pressure Relief (Safety)
Valve (PRV).
It is recommended that the
solar system is filled from the
connection points provided
using the solar filling
pump/tank available as an
optional extra.