Technical data

Page 4
The above dimensions do not include the
100mm high installation base.
The above dimensions include the 100mm high
installation base and assume the F & E cistern is
in the same cupboard.
Note: Add 100mm to the above minimum
cupboard dimensions if a ballvalve and
overflow are being fitted.
Options at Extra Cost
See standard BoilerMate A-Class SP model
manual for details of the above.
1.0 DESIGN
B
E
600mm min clear opening - if door is
located directly in front of the
appliance.
Maintenance
access
*Increase to 350mm to
provide the minimum
maintenance access to
comply with the Water
Regulations if a ballvalve
and overflow are being
fitted.
F
C
300mm
420mm
280mm
600mm
100mm
*250mm
D
A
F & E Cistern
F & E Cistern
BoilerMate A-Class Solar
Appliance Dimensions
Model Height (A) Width (B) Depth (C)
BMA 200-SP SOL 1330 560 620
BMA 220-SP SOL 1330 560 620
BMA 240-SP SOL 1575 560 620
Minimum Cupboard Dimensions
Model Height (D) Width (E) Depth (F)
BMA 200-SP SOL 1825 660 630
BMA 220-SP SOL 1980 660 630
BMA 240-SP SOL 2225 660 630
1.0 INTRODUCTION