User Guide

Table Of Contents
AV8OR Ace User’s Guide Appendix
Pub. No D200904000003 Page 7-18 Rev 1 Jul 2009
© Honeywell International Inc. Do not copy without express permission of
Honeywell.
CONNECTION TO AN EXTERNAL
TRAFFIC SOURCE
ZAON XRX - SERIAL SETUP
Configuration of the Zaon XRX
To configure the Zaon XRX, perform the following steps:
Using the XRX AIRCRAFT menu, set the aircraft type as
appropriate for your aircraft as described in the ZAON users
Manual.
Using the XRX RANGE menu, set the horizontal detection range
to 6 nm radius.
Using the XRX ALTITUDE menu, set the altitude limitation to
2500 ft.
Using the XRX COM menu, set the third party communications
to PROFILE 1.
o Verify the XRX configuration switches are set as
described in the XRX Users Guide for third-party output.
Press Mute to return to the traffic screen. This screen will show
“PROFILE 1”.
Set the configuration switches on the Zaon XRX to the correct
configuration to use the RS-232 output.
Configuration of AV8OR
To configure the AV8OR ACE to receive external traffic data,
perform the following steps:
If the Weather Source is set to “COM 1” or “COM 2”, it
must be changed to Bluetooth or a different COM port than
is used by the ZAON or None.
From the Aviation Main Menu, tap the
soft key to
open the System Setup Menu.
Highlight the Device Setup option and tap the SELECT soft
key to show the Device Setup page.
The AV8OR ACE must be set up so that the Traffic Port is
configured as “COM 1” or “COM 2”. The Type must be set
as “ZAON Traffic”.