AD-9
AIR DRYER TROUBLESHOOTING CHART
SYMPTOMS CAUSE
REMEDY
1. Test fittings, hoses, lines and connections.
Apply soap solution to detect excessive
leakage. Tighten or replace as needed then
repeat the air dryer charge-purge cycle and
observe the gauge installed in the supply
reservoir. If leakage is within limits remove gauge
from reservoir and replace drain cock or valve. If
excessive leakage is detected, continue testing.
2. Test accessories connected to supply
reservoir. Drain all air pressure from system,
disconnect all air lines leading to accessories
(fan clutch, wipers, air seats, etc.) and plug the
reservoir at disconnection point. Build air system
pressure until air dryer purges and observe
supply reservoir gauge. If leakage is no longer
excessive, repair or replace leaking accessory. If
excessive leakage is detected, continue testing.
3. Test governor leakage. Build system pressure
to governor cut-out turn off engine and apply
soap solution to governor exhaust port and
around cap. Leakage should not exceed a 1"
bubble in 5 seconds. Reduce system pressure
to 80 psi or less, and reapply soap solution.
Leakage should not exceed a 1" bubble in 5
seconds. If excessive leakage is detected in
either test, repair or replace governor.
4. Test compressor unloader leakage. Drain all
air pressure from system and remove the
governor from the compressor. Temporarily plug
the governor unloader port or air line that mated
with, or connected to, the compressor. Build air
system pressure until air dryer purges then
IMMEDIATELY SHUT OFF THE ENGINE.
Observe the air gauge in the supply reservoir. If
leakage is within limits, replace the compressor
unloaders. Reconnect the governor to the
compressor (after removing plug installed in
governor) and retest while observing supply
reservoir gauge. If excessive leakage is
detected, continue testing.
5. Test air dryer purge valve and outlet
(delivery) check valve. Drain all air pressure
from system, remove the control line connection
at the air dryer and plug the end of the air line
leading to the governor (not the air dryer control
port). Build system pressure to governor cut-out
and observe air gauge. If little or no pressure
drop is observed replace the air dryer check
valve. If pressure drop continues apply soap