BRAKE SYSTEMS DIAGNOSTIC GUIDE
POTENTIAL CONDITION/CAUSE ACTION (SERVICE MANUAL SECTION)
Inadequate air supply to chamber:
Old or broken lines Replace chamber air lines (3)
Pinhole leaks in air chamber line Replace chamber air lines (3)
Loose or damaged fittings Tighten or replace fittings (3)
Air line inner lining separation Replace chamber air lines (3)
Separation:
Plugged lines Remove blockage
Contamination Remove contamination
Valve problems:
Worn valves Repair or replace
Internal component failures Repair or replace
Seals/O-rings damaged Replace seals/O-rings
External vents blocked Remove blockage
Governor failure:
Incorrect set point Correct set point
Contamination Remove contamination
Damaged valve Repair or replace
Compressor failure:
Worn or leaking compressor Repair or replace compressor
Slipping/broken belts/drives Repair or replace belts or drives
Contamination:
No air dryer Install air dryer
Faulty air dryer Repair or replace air dryer
Dirty/damaged filter Replace air filter
Desiccant debris Remove debris
Incompatible oils Drain and refill oil
Leaking air tanks Repair or replace
Improperly set air chamber:
Too much rod free-travel Adjust brakes (2)
Slack adjuster improperly set:
Incorrect installation of slack adjuster Install slack adjuster properly (3,6)
Incorrect in-service adjustment Adjust brakes using correct procedure (2,6)
Incorrect setup of external reference control arms Perform correct setup procedure (3,6)
(Eaton-Haldex)
Worn clevis pin Replace clevis pin (3,6)
LONG STOPPING DISTANCES