F4.0 Impact Alert (IA)
The “Impact Alert”, uses a combination of distance to the vehicle ahead, plus high relative velocity, to decide when
to issue a loud solid tone, as well as a visual indicator to the driver. The red LED bar across the top of the DIU will
illuminate and “ACB Requires DRIVER INTERVENTION” will ash using the two screens below:
Screen
ashes
between
these two
displays
ACB REQUIRES
DRIVER INTERVENTION
ACB REQUIRES
DRIVER INTERVENTION
All Red LEDs Illuminated
ACB REQUIRES
DRIVER INTERVENTION
When the Impact Alert activates, the driver must immediately act to potentially avoid, or lessen the severity
of, a collision.
The impact alert can not be congured or turned off.
NOTE: At most, the adaptive cruise control with braking feature of Bendix
®
Wingman
®
Advanced
will apply
up to one-third of the vehicle’s braking capacity. The driver must apply additional braking, when necessary,
in order to maintain a safe distance from the vehicle ahead.
F4.1 Collision Mitigation
If a collision is likely to occur, and the collision mitigation feature activates the foundation brakes, the tone
of the alert will typically change and the display will be as shown below. The driver must immediately act to
potentially avoid, or lessen the severity of, a collision.
Screen
ashes
between
these two
displays
WINGMAN Adv.
BRAKING
WINGMAN Adv.
BRAKING
All Red LEDs Illuminated
WINGMAN Adv.
BRAKING
NOTE: At most, the collision mitigation feature of Bendix
®
Wingman
®
Advanced
will apply up to two-thirds
of the vehicle’s braking capacity.
F5.0 Stationary Object Alert (SOA)
Stationary Object Alert (SOA) is an alert given to the driver when the radar detects a sizeable, nonmoving
metallic object in the vehicle's path of travel. To reduce the number of false detections, such as bridges and
overhead signs, an advanced set of lters are put in place so the SOA will not warn on every stationary object.
The SOA can be congured to be on or off through Bendix
®
ACom
®
Diagnostics.
If a SOA is issued, the DIU will very briey send out an alert identical to a very brief FDA Level 2: continuous
tone and two yellow LEDs, with the display image switching between the two shown below.