Service manual
Group 59 Anti-Lock Brake System (Bendix) Troubleshooting
Installing and Removing the MPC Cartridge
With the MPC cartridge installed in the Pro-Link tool, you
can use the Bendix ABS application card.
To Install the MPC Cartridge:
1 Disconnect the vehicle adapter (containing the 12–
volt power feed) from the vehicle.
2 Seat the cartridge on the back of the Pro-Link tool.
Do not hold the cartridge at an angle. It must sit flat.
It will go only one way.
Note: The connector (edgeboard) of the cartridge
automatically lines up with the connector and the
Pro-Link unit.
3 Slide the cartridge forward until it clicks into place.
The cartridge may be left in place indefinitely.
W3003011
To Remove the MPC Cartridge:
1 Place your thumbs on the slanted surface of the
keyboard and your fingers on the cartridge.
2 Make a motion similar to snapping your fingers. The
retention latches will release the outer end of the
MPC cartridge.
3 Continue sliding the cartridge straight out until the
edgeboard is clear of the connector in the Pro-Link
tool.
W3003012
Non-Volatile Memory
The MPC cartridge has a non-volatile memory. This
means that data is not lost when the Pro-Link/MPC tool
is disconnected from the vehicle’s power source.
When the Pro-Link/MPC tool is connected to an external
power source (using the power cable in conjunction with
the data cable), the Pro-Link/MPC tool recognizes that it
is not communicating with an ECU. The “func” key is still
active, and you can access stored data for review and
printing. This includes “MPC Utilities” and “Recall Data.”
32