Service manual

Group 59 Anti-Lock Brake System (Bendix) Troubleshooting
Using the Bendix ABS Application Card and MPC Cartridge (with EC-17/AL-
7 ECU)
Perform the following steps to determine faults us-
ing the Pro-Link 9000.
1 Insert the MPC cartridge into the Pro-Link 9000
(see Installing and Removing the MPC Cartridge
page 32).
2 Plug the male end of the data cable into the Pro-Link
9000. Tighten the thumbscrews to secure the cable.
3 Remove the dust cap from the vehicle diagnostics
connector and connect the data cable to the diag-
nostics connector (1) on the vehicle.
W5000547
1) Diagnostics connector location
4 Place the vehicle ignition switch ON.
5 Verify the Pro-Link 9000 powers up properly by ob-
serving the following display.
W3003116
6 Insert the Bendix ABS application card into the MPC
cartridge (see Application Cards page 34). The
display should indicate that the ABS/ATC application
is ready to be selected.
Note: From this display, you can also use the up or
down arrows to choose either MPC Utilities or
Load All Applications for the MPC Utilities Menu
Structure (for more information, refer to the Pro-
Link/MPC operators manual).
BENDIX MPC
----Selections ----
BENDIX ABS/ATC v1.0
With BENDIX ABS/ATC v1.0 on the bottom line of
the display, press ENTER to continue to the Bendix
ABS/ATC Application Menu Structure.
Note: To exit to the previous menu, press FUNC-
TION.
7 With the Bendix ABS/ATC application running, you
can choose from the following main options (for a
owchart showing application options, see MPC
Application Menu Structure page 39):
Diagnostic Codes
Data List
Reset ECU
Test System
System Conguration
ECU Information
BENDIX ABS/ATC
VERSION 1.00
----Selections ----
DIAGNOSTIC CODES
Use the up or down arrows to scroll to the desired
option. With the Diagnostic Codes option on the
bottom line of the display, press ENTER to continue.
Note: To exit to the main menu options, press the
FUNCTION key.
36