Service manual

Group 59 Anti-Lock Brake System (Bendix) Troubleshooting
Using the Bendix ABS Cartridge (with EC-16/AL-6 ECU)
Perform the following steps to determine faults us-
ing the Pro-Link 9000.
1 Insert the Bendix ABS cartridge into the Pro-Link
9000/MPC tool.
2 Plug the male end of the data cable into the Pro-Link
9000. Tighten the thumbscrews to secure the cable.
3 Remove the dust cap from the vehicle diagnostics
connector and connect the data cable to the diag-
nostics connector (1) on the vehicle.
W5000547
1) Diagnostics connector location
4 Place the vehicle ignition switch ON.
5 Verify the Pro-Link 9000 powers up properly by ob-
serving the following display.
MPSI Pro-Link 9000
SOFTWARE COPYRIGHT
1995 VERSION 1.0
BENDIX ABS/ATC
6 Verify the Pro-Link establishes communication with
the ABS by observing a display similar to the follow-
ing.
4 SENSOR ABS
ACTIVE FAULTS YES
FAULT HISTORY YES
[ ENTER ] TO CONTINUE
7 Verify the information displayed matches the vehicle
conguration (4 sensor or 6 sensors). If it does not,
refer to the MPSI Pro-Link 9000 manual for the
Bendix ABS/ATC System to change the Pro-Link
9000 test conguration.
8 Press ENTER to access the function selections
menu.
9 If ABS/ATC does not have brackets around it, press
the left arrow to place brackets around ABS/ATC,
then press ENTER.
FUNCTION SELECTIONS
SELECT DESIRED
MENU
[ABS/ATC] Pro-Link
10 With the DIAGNOSTIC CODES menu displayed,
press ENTER to go to the faults menu.
BENDIX ABS/ATC
-----SELECTIONS -----
DIAGNOSTIC CODES
11 When the ABS MENU appears, use the up and
down arrow keys to scroll to ACTIVE FAULTS or
FAULT HISTORY, then press ENTER.
BENDIX ABS/ATC
-----SELECTIONS -----
ACTIVE FAULTS
40