Service manual

Group 59 Anti-Lock Brake System (Bendix) Troubleshooting
11 When the ABS selections menu appears, use the
down arrow key to scroll to TEST SYSTEM. Then
press ENTER.
ABS MENU
-----SELECTIONS -----
TEST SYSTEM
12 Use the up and down arrow keys to scroll to the test
of your choice, then press ENTER to run the test.
13 When system testing is complete, press FUNC to
return to the selections menu. Use the up or down
arrow keys to scroll to DATA LIST, then press
ENTER.
14 The Pro-Link 9000 will display the current value of
four parameters. Press the down arrow to view addi-
tional parameters. The status of the following
parameters can be displayed by the Pro-Link 9000.
L FRONT MPH
R FRONT MPH
L REAR MPH
R REAR MPH
L MIDDLE MPH
R MIDDLE MPH
BATT VOLTAGE
TRACTOR LAMP
WARNING LAMP
RETARDER RELAY
ENGINE IDLE
SBEND RELAY
ENGINE DATA LINK
RETARDER DATA LINK
15 At any time, press FUNC to move back to the previ-
ous menu (one level higher).
16 When all testing is complete, turn the vehicle igni-
tion switch to OFF before disconnecting the Pro-Link
9000.
43