STEP 1
(Selecting Site)
Before installing your new lift, check the following.
1. LIFT LOCATION: Always use architects plans when
available. Check layout dimension against floor plan
requirements making sure that adequate space if avail-
able.
2. OVERHEAD OBSTRUCTIONS: The area where the
lift will be located should be free of overhead obstruc-
tions such as heaters, building supports, electrical lines
etc.
3. DEFECTIVE FLOOR: Visually inspect the site where
the lift is to be installed and check for cracked or
defective concrete.
5. Lift is designed for INDOOR INSTALLATION ONLY.
Outdoor use permitted only if covered and dry. Always
follow warnings illustrated on equipment labels.
STEP 2
(Floor Requirements)
This lift must be installed on a solid level con-
crete floor with no more than 3° of slope. Failure
to do so could cause personal injury or death.
A level floor is suggested for proper use and
installation and level lifting. If a floor is of questionable
slope, consider a survey of the site and/or the possibility of
pouring a new level concrete slab.
t DO NOT install or use this lift on any asphalt surface
or any surface other than concrete.
t DO NOT install or use this lift on expansion seams
or on cracked or defective concrete.
t DO NOT install or use this lift on a second / elevated
floor without first consulting building architect.
CONCRETE SPECIFICATIONS
LIFT MODEL CONCRETE REQUIREMENTS
HD-9ST 3.5” Min. Thickness / 2,500 PSI
HD-9 3.5” Min. Thickness / 2,500 PSI
HD-9STX 3.5” Min. Thickness / 2,500 PSI
HD-9XW 3.5” Min. Thickness / 2,500 PSI
HD-9XL 3.5” Min. Thickness / 2,500 PSI
All models MUST be installed on 2500 PSI concrete only
conforming to the minimum requirements shown above.
New concrete must be adequately cured by at least
28 days minimum.
IMPORTANT NOTICE
These instructions must be followed to ensure proper installation and operation of your lift. Failure
to comply with these instructions can result in serious bodily harm and void product warranty.
Manufacturer will assume no liability for loss or damage of any kind, expressed or implied resulting
from improper installation or use of this product.
PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATION
t Rotary Hammer Drill or Similar
t 3/4” Masonry Bit
t Hammer
t 4 Foot Level
t Open-End Wrench Set: SAE /Metric
t Socket And Ratchet Set: SAE/ Metric
t Hex-Key / Allen Wrench Set
t Medium Crescent & Pipe Wrenches
t Torque Wrench
t Crow Bar
t Chalk Line
t Medium Flat Screwdriver
t Tape Measure: 25 Foot Minimum
t Needle Nose Pliers
TOOLS REQUIRED
An air supply (75-90PSI Min / 5 CFM Min.) will be required for the safety-lock mechanisms. See Step 11.
IMPORTANT NOTE:
BendPak lifts are supplied with installation instructions and concrete fasteners meeting the criteria as prescribed
by the American National Standard "Automotive Lifts - Safety Requirements for Construction, Testing, and
Validation" ANSI/ALI ALCTV-2011. Lift buyers are responsible for any special regional structural and/or seismic
anchoring requirements specied by any other agencies and/or codes such as the Uniform Building Code (UBC)
and/or International Building Code (IBC).