IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS EUROPEAN USERS 400V 50Hz SUPPLY DETAILS ARE INCLUDED WITH ELECTRICAL CONTROL BOX. DISREGARD SUPPLY WIRING DETAILS IN THIS MANUAL PLEASE READ THE ENTIRE CONTENTS OF THIS MANUAL PRIOR TO INSTALLATION AND OPERATION. BY PROCEEDING WITH LIFT INSTALLATION AND OPERATION YOU AGREE THAT YOU FULLY UNDERSTAND AND COMPREHEND THE FULL CONTENTS OF THIS MANUAL. FORWARD THIS MANUAL TO ALL OPERATORS.
TWO-POST SURFACE MOUNTED AUTO AND TRUCK LIFT This instruction manual has been prepared especially for you. Your new lift is the product of over 40 years of continuous research, testing and development; it is the most technically advanced lift on the market today. READ THIS ENTIRE MANUAL BEFORE INSTALLATION & OPERATION BEGINS. RECORD HERE THE LIFT AND POWER UNIT INFORMATION WHICH IS LOCATED ON THE SERIAL NUMBER DATA PLATES ON THE LIFT AND ON THE POWER UNIT Power Unit Model # Power Unit Date Of Mfg.
OWNER’S RESPONSIBILITY IMPORTANT NOTICE To maintain the lift and user safety, the responsibility of the owner is to read and follow these instructions: Do not attempt to install this lift if you have never been trained on basic automotive lift installation procedures. Never attempt to lift components without proper lifting tools such as forklift or cranes. Stay clear of any moving parts that can fall and cause injury.
Contents TABLE OF CONTENTS Page No. Warranty / Serial Number Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Definitions of Hazard Levels . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Owner’s Responsibility . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .
INSTALLER / OPERATOR PLEASE READ AND FULLY UNDERSTAND. BY PROCEEDING YOU AGREE TO THE FOLLOWING: Please read entire manual prior to installation. Do not operate this machine until you read and understand all the dangers, warnings and cautions in this manual. For additional copies or further information, contact: t I have visually inspected the site where the lift is to be installed and verified the concrete to be in good condition and free of cracks or other defects.
INTRODUCTION 1. Carefully remove the crating and packing materials. CAUTION! Be careful when cutting steel banding material as items may become loose and fall causing personal harm or injury. 2. Check the voltage, phase and proper amperage requirements for the motor shown on the motor plate. Wiring should be performed by a certified electrician only. IMPORTANT SAFETY INSTRUCTIONS Read these safety instructions entirely.
TOOLS REQUIRED t t t t t t t Rotary Hammer Drill or Similar 3/4” Masonry Bit Hammer 4 Foot Level Open-End Wrench Set: SAE/Metric Socket And Ratchet Set: SAE/Metric Hex-Key / Allen Wrench Set t t t t t t t Large Crescent Wrench Large Pipe Wrench Crow Bar Chalk Line Medium Flat Screwdriver Tape Measure: 25 Foot Minimum Needle Nose Pliers IMPORTANT NOTICE These instructions must be followed to ensure proper installation and operation of your lift.
When removing the lift from shipping angles pay close attention as the posts can slide and can cause injury. Prior to removing the bolts make sure the posts are held securely by a fork lift or some other heavy lifting devise. PARTS INVENTORY Be sure to take a complete inventory of parts prior to beginning installation.
FLOOR PLAN XPR-12CL XPR-12CL-192 XPR-12CL-LWB XPR-12CL-LWB-192 Lifting Capacity 12,000Lbs. / 5443Kg. 12,000Lbs. / 5443Kg. 12,000Lbs./ 5443Kg. 12,000Lbs. / 5443Kg. Max Capacity/ Front Axle 6,000 lbs. / 2722 Kg. 6,000 lbs. / 2722 Kg. 6,000 lbs. / 2722 Kg. 6,000 lbs. / 2722 Kg. Max Capacity/ Rear Axle 6,000 lbs. / 2722 Kg. 6,000 lbs. / 2722 Kg. 6,000 lbs. / 2722 Kg. 6,000 lbs./ 2722 Kg. 170" / 4318 mm. (*) 192.7" / 4895 mm. 170” / 4318 mm. (*) 192.7” / 4895 mm. 155" / 3937 mm.
FLOOR PLAN XPR-15CL XPR-15CL-192 XPR-18CL XPR-18CL-192 15,000Lbs. / 6804Kg. 15,000Lbs. / 6804Kg. 18,000Lbs. / 8165Kg. 18,000Lbs. / 8165Kg. Max Capacity/ Front Axle 7,500 lbs. / 3402 Kg. 7,500 lbs. / 3402 Kg. 9,000 lbs. / 4082 Kg. 9,000 lbs. / 4082 Kg. Max Capacity/ Rear Axle 7,500 lbs. / 3402 Kg. 7,500 lbs. / 3402 Kg. 9,000 lbs. / 4082 Kg. 9,000 lbs. / 4082 Kg. 170" / 4318 mm. (*) 192.7" / 4895 mm. 170” / 4318 mm. (*) 192.7” / 4895 mm. 155" / 3937 mm. 155" / 3937 mm. 155" / 3937 mm.
CLEARANCES XPR-12CL/15CL/18CL APPROACH LIFT HEIGHT CLEARANCE NOTE: There must be a 1” MIN distance from top of lift to nearest obstruction.
STEP 3 (Column Preparation) COMPLETE THE FOLLOWING PRIOR STANDING UP COLUMNS. Cable routed up and across Overhead Assembly to opposite carriage. Threaded cable end from other side of lift. 1. Slide Lift Head up Column to aid in Pulley removal and Equalizer Cable routing. (See Fig 3.1) Fig 3.1 Power Side Column depicted NOTE: Column hidden for clarity Fig 3.4 4. Install the straight and elbow Cylinder Fittings in Cylinder Ports.
6. Route both Hoses in their respective Columns PRIOR to raising Columns to their vertical position. When routing the Hydraulic Hose through the Columns, make sure to route through the Retaining Clipswelded inside each Column. Make sure that the Hose is clear of any moving parts. It may be necessary to tie Hose clear of obstructions by using nylon tie straps or wire. Refer to Step 10. Fig 3.
HOSE ROUTING 14
FLOOR PLAN A APPROACH Model A Capacity XPR-12CL XPR-15CL XPR-18CL 155” / 3937 mm 155” / 3937 mm 155” / 3937 mm 12,000 LBS 15,000 LBS 18,000 LBS STEP 4 line to layout an alignment line for the Column locations. Keep all dimensions square within 1/8” (3mm) or malfunctioning of the lift can occur. (See Fig 4.1) (Site Layout) 1. Determine which side of the lift will be the approach side. 2. Now determine where the power unit will be located.
STEP 5 5. Insert the shims as necessary under the Base Plate so that when the anchor bolts are tightened, the Columns will be plumb. (See Fig. 5.3) (Installing The POWERSIDE Column) NOTE: BENDPAK LIFTS ARE SUPPLIED WITH INSTALLATION INSTRUCTIONS AND CONCRETE FASTENERS MEETING THE CRITERIA AS PRESCRIBED BY THE AMERICAN NATIONAL STANDARD "AUTOMOTIVE LIFTS - SAFETY REQUIREMENTS FOR CONSTRUCTION, TESTING, AND VALIDATION" ANSI/ALI ALCTV-2011.
STEP 7 STEP 8 (Mounting the Overhead Assembly) (Mounting the Hydraulic Power Unit) IN ORDER TO ROUTE THE EQUALIZER CABLES THE SHEAVES MUST BE REMOVED. NOTE: 1. Attach the power unit to the POWER SIDE Column. Install the vibration dampener between the power unit and the power unit mounting plate on the Power Side Column, using four M8 hex head bolts and nuts supplied. (See Fig 8.1) 1. Remove all of the Equalizer pulleys in preparation of installing the Overhead Assembly. 2.
DO NOT RUN POWER UNIT WITHOUT OIL. DAMAGE TO POWER UNIT PUMP CAN OCCUR. THE POWER UNIT MUST BE KEPT DRY. DAMAGE TO POWER UNIT CAUSED BY WATER OR OTHER LIQUIDS SUCH AS DETERGENTS, ACID ETC., IS NOT COVERED UNDER WARRANTY. OPERATE LIFT ONLY BETWEEN TEMPERATURES OF 41 °- 104° F. ANY IMPROPER ELECTRICAL INSTALLATION MAY DAMAGE POWER UNIT MOTOR AND RESULTING DAMAGE WILL NOT BE COVERED UNDER WARRANTY. MOTOR CAN NOT RUN ON 50HZ WITHOUT A PHYSICAL CHANGE IN MOTOR. USE A SEPARATE CIRCUIT BREAKER FOR EACH POWER UNIT.
NOTE: ENSURE THAT BOTH THE POWER SIDE & OFF SIDE SAFETIES ENGAGE PROPERLY PRIOR TO LIFT OPERATION. MAKE SURE TO KEEP THE SAFETY CABLE CENTERED WHEN TIGHTENING JAM NUTS ON SAFETY. Fig 9.3 NOTE: Top plate cut away for clarity Safety Cable Insert non-looped end of safety cable through hole in Column Fig 9.
STEP 10 (Installing Hydraulic Lines) 1. Install the bulkhead tee fitting into the Power Side Column. The through hole is located approximately 90 inches from the floor on the back wall of the Power Side Column. STEP 11 2. Connect the Power Side cylinder hose to the tee fitting. Be sure to route the hose through the retainer clips inside the posts.
STEP 12 Fig. 11.2 (Installing Overhead Micro Switch) Equalizer Cables MICROSWITCH WIRE MUST BE RUN THROUGH CLIPS IN POST AND OVERHEAD ASSEMBLY. FAILURE TO DO SO CAN CAUSE DAMAGE TO LIFT OR TO VEHICLES. Sheave Brackets 1. Install the overhead Microswitch as shown below. Be sure to keep wire clear of moving parts. (See Fig.12.1) Sheaves Fig. 11.3 Threaded Cable End Microswitch Box Threaded cable end comes down from Overhead Assembly and into hole on top of carriage plate. Microswitch Cover Fig.
3. Route wire up through Column and across Overhead Assembly through hole in Overhead Assembly into the Microswitch box. (See Fig. 12.3) 2. Install the 90° fitting w/ O-ring into the power port of the power unit. Use teflon tape on the pipe fittings ONLY. Connect power unit hose assembly to the 90° w/O-ring fitting on power unit. (See Fig. 13.2) Microswitch Wire Power unit hose assembly Power unit 90° fitting with O-ring Microswitch Wire Clips Fig. 13.2 3.
THE ARM RESTRAINT GEARS MUST BE POSITIONED PROPERLY. CONFIRMATION OF PROPER GEAR ENGAGEMENT MUST BE MADE PRIOR TO THE OPERATION OF THE LIFT. PERIODIC INSPECTION IS REQUIRED. FAILURE TO INSPECT THE ARM RESTRAINT GEARS ON ALL FOUR ARMS PROPERLY CAN RESULT IN DAMAGE TO THE VEHICLE OR INJURY AND/OR DEATH. Screw 4. Place each Gear Ring against the Lift Head Pin and align the holes in the Gear Ring with the threaded holes in the Arm Ears.
NOTE: EACH ARM RESTRAINT ASSEMBLY MUST BE INSPECTED BEFORE EACH AND EVERY TIME THE LIFT IS OPERATED. DO NOT OPERATE THE LIFT IF ANY OF THE FOUR ARM RESTRAINT SYSTEMS ARE NOT FUNCTIONING PROPERLY. REPLACE ANY BROKEN COMPONENTS OR COMPONENTS WITH BROKEN TEETH ONLY WITH AUTHORIZED OR APPROVED REPLACEMENT PARTS.
CARRIAGE STOP BOLT INSTALLATION YOU MUST RE-INSTALL TOP CARRIAGE-STOP BOLT (SHOWN BELOW). TIGHTEN CARRIAGE-STOP BOLT TO 2-3 FT.-LBS. OF TORQUE UPON FINAL INSTALLATION INSPECTION. THESE INSTRUCTIONS MUST BE FOLLOWED TO ENSURE PROPER INSTALLATION AND OPERATION OF YOUR LIFT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS CAN RESULT IN SERIOUS BODILY INJURY AND/OR DEATH AND/OR VOID PRODUCT WARRANTY.
DO NOT PERFORM ANY MAINTENANCE OR INSTALLATION OF ANY COMPONENTS WITHOUT FIRST ENSURING THAT ELECTRICAL POWER HAS BEEN DISCONNECTED AT THE SOURCE OR PANEL AND CANNOT BE RE-ENERGIZED UNTIL ALL MAINTENANCE AND/OR INSTALLATION PROCEDURES ARE COMPLETED. IMPORTANT POWER-UNIT INSTALLATION NOTES n DO NOT run Power Unit with no oil. Damage to pump can occur. n The Power Unit must be kept dry. Damage to Power Unit caused by water or other liquids such as detergents, acid etc., is not covered under warranty.
STEP 16 STEP 15 (Lift Start Up / Final Adjustments) (Power Unit Connection) 1. Have a certified electrician run the power supply to motor. Refer to the data plate found on the motor for proper power supply and wire size. DURING THE START-UP PROCEDURE, OBSERVE ALL OPERATING COMPONENTS AND CHECK FOR PROPER INSTALLATION AND ADJUSTMENT. DO NOT ATTEMPT TO RAISE VEHICLE UNTIL A THOROUGH OPERATIONAL CHECK HAS BEEN COMPLETED.
POST-INSTALLATION CHECK-OFF NOTE: There will be initial stretching of the cables and/or with increased loads. Adjust the cables as outlined above a week after first use, then every three to six months thereafter depending on usage and/or to compensate for stretch.
OPTIONAL EQUIPMENT INSTALLATION 30
OPTIONAL AND STANDARD ACCESSORIES Optional Equipment available through your Authorized BendPak Dealer.
If the lift was provided with Lift Arm Foot Guards, install the shorter Foot Guard on the shorter Arm Assembly and the longer Foot Guard on the longer Arm Assembly. To install firmly squeeze the ends of the Foot Guard inwards and insert the ends underneath the bent ends of the arm support. Release to allow the Foot Guard to spring into place. Check to be sure that Foot Guard is firmly in place. Repeat this step for each Arm Assembly Foot Guard.
STEP 19 (Operation Instructions) • Shall display the lift manufacturer’s operating instructions; ALI/SM 93-1, ALI Lifting It Right safety manual; ALI/ST-90 ALI Safety Tips card; ANSI/ALI ALOIM-2000, American National Standard for Automotive Lifts-Safety Requirements for Operation, Inspection and Maintenance; and in the case of frame engaging lifts, ALI/ LP-GUIDE, Vehicle Lifting Points/Quick Reference Guide for Frame Engaging Lifts; in a conspicuous location in the lift area convenient to the operator.
LIFT OPERATION SAFETY (CONT’D) • ALWAYS load vehicle on lift carefully. Position the lift adapters to contact at the vehicle manufacturer’s recommended lift points. Raise lift until adapters contact vehicle. Check adapters for secure contact with vehicle. Raise lift to desired working height. (See Fig.19.1) WHEN LOWERING THE LIFT PAY CAREFUL ATTENTION THAT ALL PERSONNEL AND OBJECTS ARE KEPT CLEAR. ALWAYS KEEP A VISUAL LINE OF SITE ON THE LIFT AT ALL TIMES. ALWAYS MAKE SURE THAT ALL LOCKS ARE DISENGAGED.
LIFT OPERATION SAFETY (CONT’D) Fig. 19.2 TYPICAL LIFTING POINTS Fig. 19.3 MANY SPECIALTY OR MODIFIED VEHICLES CANNOT BE RAISED ON A TWO-POST FRAME ENGAGING LIFT. CONTACT VEHICLE MANUFACTURER FOR RAISING OR JACKING DETAILS. 4. Position vehicle for proper weight distribution arms under vehicle to allow adapters to contact at the manufacturer’s recommended pick up points. NOTE: ALLOW (2) SECONDS BETWEEN MOTOR STARTS. FAILURE TO COMPLY MAY CAUSE MOTOR BURNOUT. 7. Stop before making contact with vehicle.
LIFT OPERATION SAFETY (CONT’D) 10. Continue to raise to desired height only if vehicle is secure on lift. WHEN LOWERING THE LIFT PAY CAREFUL ATTENTION THAT ALL PERSONNEL AND OBJECTS ARE KEPT CLEAR. ALWAYS KEEP A VISUAL LINE OF SITE ON THE LIFT AT ALL TIMES. ALWAYS MAKE SURE THAT ALL LOCKS ARE DISENGAGED. IF ONE OF THE LOCKS INADVERTENTLY LOCKS ON DESCENT THE LIFT AND/OR VEHICLE MAY DISRUPT CAUSING PERSONAL INJURY OR DEATH. 11.
LIFT OPERATION SAFETY (CONT’D) • Always replace ALL FAULTY PARTS before lift is put back into operation. • Monthly: Check equalizer cable tension. Adjust per lift installation instructions. • Daily: Make a visual inspection of ALL MOVING PARTS and check for excessive signs of wear. • Monthly: Lubricate locking latch shafts. Push latch handle several times for oil to penetrate pivot points. • Daily: Check safety locks to ensure they are in good operating condition.
TO RAISE LIFT t t Read operating and Safety manuals before using lift. Always lift a vehicle according to the manufacturers recommended lifting points. Position vehicle between columns. Adjust swing arms so that the vehicle is positioned with the center of gravity midway between pads. Use truck adapters as needed. Never exceed 9” of Pad height. NEVER use lift pad assemblies without rubber slip over pads in place. Raise the vehicle by depressing button until the vehicle just lifts off the ground.
WIRE ROPE INSPECTION AND MAINTENANCE t Lifting cables should be replaced every three - five years or when visible signs of damage are apparent. DO NOT USE LIFT WITH DEFECTIVE / WORN CABLES. t Lifting cables should be maintained in a well-lubricated condition at all times. Wire rope is only fully protected when each wire strand is lubricated both internal and external. Excessive wear will shorten the life of the wire rope.
41
Safe Lift Operation Automotive and truck lifts are critical to the operation and profitability of your business. The safe use of this and other lifts in your shop is critical in preventing employee injuries and damage to customer’s vehicles. By operating lifts safely you can ensure that your shop is profitable, productive and safe. Safe operation of automotive lifts requires that only trained employees should be allowed to use the lift.
t DO NOT leave the controls while the lift is still in motion. t DO NOT stand directly in front of the vehicle or in the bay when vehicle is being loaded or driven into position. t DO NOT go near vehicle or attempt to work on the vehicle when being raised or lowered. t REMAIN CLEAR of lift when raising or lowering vehicle. t DO NOT rock the vehicle while on the lift or remove any heavy component from vehicle that may cause excessive weight shift.
LIFT WILL NOT RAISE POSSIBLE CAUSE 1. Air in oil, (1,2,8,13) 2. Cylinder binding, (9) 3. Cylinder leaks internally, (9) 4. Motor run backward under pressure, (11) 5. Lowering valve leaks, (3,4,6,10,11) 6. Motor runs backwards, (7,14,11) 7. Pump damaged, (10,11) 8. Pump won’t prime, (1,8,13,14,3,12,10,11) 9. Relief valve leaks, (10,11) 10. Voltage to motor incorrect, (7,14,11) REMEDY INSTRUCTION 1. Check for proper oil level. . . . . . . . . . . . . . . . . . . . . . . . . .
MOTOR WILL NOT RUN POSSIBLE CAUSE 1. Fuse blown, (5,2,1,3,4) 2. Limit switch burned out, (1,2,3,4) 3. Microswitch burned out, (1,2,3,4) 4. Motor burned out, (1,2,3,4,6) 5. Voltage to motor incorrect, (2,1,8) REMEDY INSTRUCTIONS 1. Check for correct voltage . . . . . . . . . . . . . . . . . . Compare supply voltage with voltage on motor name tag. Check that the wire is sized correctly. N.E.C table 310-12 requires AWG 10 for 25 amps. 2. Check motor is wired correctly . . . . . . . . . . . . . . . .
WILL NOT RAISE LOADED LIFT POSSIBLE CAUSE 1. Air in oil, (1,2,3,4) 2. Cylinder binding, (5) 3. Cylinder leaks internally, (5) 4. Lift overloaded, (6,5) 5. Lowering valve leaks, (7,8,1,5,9) 6. Motor runs backwards, (10,12,9) 7. Pump damaged, (5,9) 8. Pump won’t prime, (1,2,3,4,5,11,9) 9. Relief valve leaks, (8,5,9) 10. Voltage to motor incorrect, (10,12,5) REMEDY INSTRUCTIONS 1. Check oil level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POSSIBLE CAUSE 1. Air in oil, (1,2,3) 2. Check valve leaks, (6) 3. Cylinders leak internally, (7) 4. Lowering valve leaks, (4,5,1,7,6) 5. Leaking fittings, (8) LIFT WILL NOT STAY UP REMEDY INSTRUCTIONS 1. Check oil level . . . . . . . . . . . . . . . . . . ................. The oil level should be up to the bleed screw in the reservoir with the lift all the way down. 2. Oil seal damaged and cocked . . . . . . . . . . . . . . . . . . . . . . . . Replace oil seal around pump shaft. 3.
1. SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING NOTE: UNLESS OTHERWISE SPECIFIED. 2 3 NEXT ASSEMBLY 5260563 5260565 5260567 5260569 1 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING TM NAME DATE 01/29/2010 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2 3 NEXT ASSEMBLY 5260564 5260571 5260576 5260577 1 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING TM NAME DATE 02/03/2010 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
1. 2. 3. 4. 5. INSERT PARTS BAG INTO PARTS BOX FOR SHIPMENT SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING THREAD 5535011 ONTO CABLES WITH 5545345 FOR SHIPMENT FOR 5220116 SPECIFICATIONS REFER TO PART SPECIFICATION FORM (*)5520116 QTY FOR REFERENCE ONLY NOTE: UNLESS OTHERWISE SPECIFIED. NEXT ASSEMBLY 5260567 5260569 ☺ DIMENSIONS ARE IN MM TM NAME DATE 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC.
20 29 28 30 31 5 32 26 19 9 4 3 7 25 16 15 22 2 1 18 12 21 23 24 17 11 13 14 10 27 8 6 SCALE: 1:22 5250041 SHEET 2 OF 2 A REV XPR-12CL/12CL-LWB PARTS BOX SIZE DWG. NO. A TITLE: 1645 LEMONWOOD DR.
1. 2. 3. 4. INSERT PARTS BAG INTO PARTS BOX FOR SHIPMENT SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING THREAD 5535011 ONTO CABLES WITH 5545345 FOR SHIPMENT FOR 5220116 SPECIFICATIONS REFER TO PART SPECIFICATION FORM NEXT ASSEMBLY (*) 5520116 QTY FOR REFERENCE ONLY 5260571 NOTE: UNLESS OTHERWISE SPECIFIED. ☺ DIMENSIONS ARE IN MM TM NAME DATE 12/16/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC.
23 5 9 30 32 29 28 11 19 22 2 31 4 3 7 25 27 21 16 24 15 18 12 1 26 10 17 13 14 6 20 8 SCALE: 1:25 5250043 SHEET 2 OF 2 A REV XPR-15CL PARTS BOX SIZE DWG. NO. A TITLE: 1645 LEMONWOOD DR.
1. 2. 3. 4. INSERT PARTS BAG INTO PARTS BOX FOR SHIPMENT SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING THREAD 5535011 ONTO CABLES WITH 5545345 FOR SHIPMENT FOR 5220116 SPECIFICATIONS REFER TO PART SPECIFICATION FORM (*) 5520116 QTY FOR REFERENCE ONLY NOTE: UNLESS OTHERWISE SPECIFIED. NEXT ASSEMBLY 5260576 ☺ DIMENSIONS ARE IN MM TM NAME DATE 12/16/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC.
23 5 9 30 32 29 28 11 22 19 2 31 4 3 7 27 25 21 16 24 15 18 12 1 26 10 17 13 14 8 6 20 SCALE: 1:25 5250044 SHEET 2 OF 2 A REV XPR-18CL PARTS BOX SIZE DWG. NO. A TITLE: 1645 LEMONWOOD DR.
1. 2. 3. 4. 5. INSERT PARTS BAG INTO PARTS BOX FOR SHIPMENT SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING THREAD 5535011 ONTO CABLES WITH 5545345 FOR SHIPMENT FOR 5220116 SPECIFICATIONS REFER TO PART SPECIFICATION FORM (*) 5520116 QTY FOR REFERENCE ONLY NOTE: UNLESS OTHERWISE SPECIFIED. NEXT ASSEMBLY 5260563 5260565 ☺ DIMENSIONS ARE IN MM TM NAME DATE 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC.
25 20 5 9 31 30 32 29 11 28 19 2 4 3 27 26 24 21 16 23 15 7 1 10 18 12 17 13 8 14 6 22 A SCALE: 1:25 5250045 SHEET 2 OF 2 A REV XPR-12CL/12CL-LWB EXTENDED PARTS BOX SIZE DWG. NO. TITLE: 1645 LEMONWOOD DR.
INSERT PARTS BAG INTO PARTS BOX FOR SHIPMENT SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING THREAD 5535011 ONTO CABLES WITH 5545345 FOR SHIPMENT FOR 5220116 SPECIFICATIONS REFER TO PART SPECIFICATION FORM (*) 5520116 QTY FOR REFERENCE ONLY NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2. 3. 4. NEXT ASSEMBLY 5260564 ☺ DIMENSIONS ARE IN MM TM NAME DATE 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC.
26 5 22 31 32 30 29 12 10 20 2 4 3 28 8 24 17 19 16 1 7 13 18 25 27 21 11 15 14 6 9 23 SCALE: 1:25 5250046 SHEET 2 OF 2 A REV XPR-15CL EXTENDED PARTS BOX SIZE DWG. NO. A TITLE: 1645 LEMONWOOD DR.
6 A 2 SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2. 1 3 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING 5 9 NAME 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4895 155-1907.6mm [6-75"] 3033 2663 DRIVE THRU 3941 3617 343-2095.6mm [13.5-82.5"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 62 765-1473mm A SCALE: 1:50 5260563 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-12CL-192 PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
1. 2. 6 A 2 SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 1 3 5 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING NAME 7 DETAIL A SCALE 1 : 12 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4895 151-1930.6mm [6-75"] 3033 2663 DRIVE THRU 3941 3617 339-2091.6mm [13.375-82.375"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 64 945-1474mm A SCALE: 1:50 5260564 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-15CL-192 PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
6 A 2 SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2. 1 3 4 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING NAME 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4895 3033 2663 DRIVE THRU 3941 3617 342-2094.6mm [13.5-82.5"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 66 154-1906.6mm [6-75"] 902-1819mm A SCALE: 1:50 5260565 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-12CL-LWB-192 PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
5 A 2 SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2. 1 3 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING 4 6 10 DATE 12/15/2015 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4285 3033 2663 DRIVE THRU 3941 3617 343-2095.6mm [13.5-82.5"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 68 155-1907.6mm [6-75"] 765-1473mm A SCALE: 1:50 5260567 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-12CL PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
1 A 5 1. 2. 2 SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 69 3 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING TM NAME 7 8 12/15/2015 DATE PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4285 155-1907.6mm [6-75"] 3033 2663 DRIVE THRU 3941 3617 343-2095.6mm [13.5-82.5"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 70 902-1819mm A SCALE: 1:50 5260569 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-12CL-LWB PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
5 2 A SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 1. 2. 1 3 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING TM NAME 12/16/2015 DATE 7 8 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4285 3033 2663 DRIVE THRU 3941 3617 339-2019.6mm [13.375-82.375"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 72 155-1907.6mm [6-75"] 945-1474mm A SCALE: 1:50 5260571 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-15CL PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
1 2 5 1. 2. A SEE SHIPPING INSTRUCTIONS FOR FINAL PACKAGING ALL LABELS TO BE APPLIED TO POSTS AFTER PAINTING. SEE ATTACHED LABEL PLACEMENT SHEET. NOTE: UNLESS OTHERWISE SPECIFIED. 73 DIMENSIONS ARE IN MM ☺ DO NOT SCALE DRAWING TM NAME 12/16/2015 DATE 7 6 10 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF BENDPAK INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF BENDPAK INC. IS PROHIBITED.
4285 3033 2663 DRIVE THRU 3941 3617 339-2091.6mm [13.375-82.375"] WITH 63mm [2.5"] & 125mm [5"] ADAPTER 74 155-1907.6mm [6-75"] 945-1474mm A SCALE: 1:50 5260576 SIZE DWG. NO. SHEET 2 OF 2 A REV XPR-18CL PRODUCTION LIFT VER E TITLE: 1645 LEMONWOOD DR.
Declaration of Conformity The equipment which accompanies this declaration is in conformity with EU Directive: 2006/42/EC Machinery Directive Manufacturer BendPak Inc. 1645 Lemonwood Dr Santa Paula Ca, 93060 USA A copy of the Technical file for this equipment is available from: CCQS UK Ltd., Level 7, Westgate House, Westgate Rd., London W5 1YY UK Description of Equipment Two-Column Vehicle Service Lift XPR-12CL XPR-12CL-LWB XPR-12CL-192 XPR-12CL-LWB-192 XPR-15CL XPR-15CL-192 12K Cap.
TWO‐POST LIFTS/FOUR‐POST LIFTS WARRANTY Better Products – Better Service – Better Value Duration: From the date of purchase by original Purchaser or 60‐24‐12 months from the date of shipment by BendPak or whichever comes first.
MAINTENANCE / INSPECTION RECORDS ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ _________________________________________________________________
NOTES ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ _______________________