Unit installation

TAKING
DELIVERY
AND
UNPACKING
Note:
The
consignee
is
responsible
for
ensuring that
the
packages
have arrived
in
good condition. Examine
the
packages
for
damages,
if
found, note
the
same
on
carriers'
bill
of
lading
and
make
a
claim
to the
carrier.
Each
unit
is
carefully
inspected before leaving
our
factory.
Package
(1) The
crated boiler (assembled)
Package
(2) The oil
burner pack:
1
-
Choice
of
Burner
1 -
Damper Motor
&
Chain
1 -
Vz"
Drain Valve
1 -
Pressure Reducing Valve
1 -
N.O.
Zone
Valve
2-24
VA
Transformers
1
-
Pressure Relief Valve
1
-
Single Aquastat
1 -
Wiring
Harness
1
-
Triple Aquastat Relay
1
-
Nozzle
3
-
Wells
1
-
Tridicator
1
-
Triple Aquastat
1 -
Blocked Flue Sensor
2 -
Circulator Pumps
c/w
Flanges
Please note:
The two
circulator pumps
are
required
for
proper operation
of
this boiler.
Installation
of
this unit should
be in
accordance with
the
regulations
of the
authorities having
jurisdiction.
Reference
should
be
made
to:
hi
Canada,
CSA
B139,
"Installation Code
for Oil
Burning Equipment"
for
recommended
installation
practices;
In the
United
States,
UL
391
"Solid-Fuel
and
Combination-Fuel
Central
and
Supplementary
Furnaces
"
and UL 726
"Oil Fired Boiler Assemblies".
ASSEMBLY
Benjamin
"CC500"
boilers
are
factory assembled.
The
burner
and
controls
are
field
mounted using
the
wiring
harness supplied. Other wiring
for the
thermostats
and
zone valves
are not
supplied.(see wiring diagram
on
page
12)
CHIMNEY
AND
SMOKE
PIPES
(For
proper
set up, see the
diagram
on
page
10)
The
specification
of the
chimney
to be
used must comply
with
the
requirement that other than
solid-fuel/oil
combinations
and
add-ons,
wood burning
appliances
shall
not be
connected
to a
venting system serving
an
appliance
vented
by
another type
of
fuel.
Connect
the
boiler
to an
approved solid
fuel
factory-built chimney:
In
CANADA-
CAN/ULC
S629 standard
for
650°
F
chimney;
In the
UNITED
STATES-UL103
Chimneys
for
Residential Type
and
Building Heating Appliances, Factory Built
or a
safe, clean, sound condition, masonry chimney equipped with
an
approved liner:
In
CANADA-CAN/ULC-S635-M90
Standard
for
Lining Systems
for
existing masonry
or
Factory Built Chimneys
and
Vents;
hi
the
UNITED
STATES-UL1777
Chimney Liners (e.g., stainless steel, clay,
etc.).
The
chimney must
be
equivalent
to a
minimum
of
7"
round inside diameter,
or 8"
round maximum.
The
chimney must
be
capable
of
maintaining
a
negative
updraft
at all
times
and in all
conditions. Carefully inspect
the
chimney
for
safety
and
dirt before making connections. Place
the
boiler
as
close
to the
chimney
as
possible.
The
smoke pipe should
be
blue
or
black steel,
24
ga.
or
heavier.
Use as few
turns
as
possible between
the
boiler
and
the
chimney,
as
each
90°
elbow adds
10'
of
restriction
and a 45°
elbow adds
5'
of
restriction.
The
draft
regulator
should
be 7
"
diameter
and set at
-.04
W.C.
to
open. Install
the
regulator
a
minimum
of
18
"
and a
maximum
of
24
"
from the
boiler breech. Avoid long horizontal runs
of
smoke pipe. Maintain
a
minimum
of
Vz"
rise
per
foot
of
pipe
from
the
boiler
to the
chimney.
DO
NOT
run
the
pipe downhill
from the
boiler
to the
chimney. Confirm that
the
installation clearances
are met
or
exceeded. Secure
all
smoke pipe joints with three sheet metal screws
in
each joint.
DO
NOT
pass
the
smoke pipes through
a
wall, floor
or
ceiling
to
reach
the
chimney.
-1-