12. Ecological information
(a) Ecotoxicity
Very toxic to aquatic life with long lasting effects.
Chemical Name
Toxicity to Algae
Toxicity to Fish
Toxicity to
Microorganisms
Daphnia Magna
(Water Flea)
Copper
7440-50-8
96h EC50: 0.031 - 0.054
mg/L
(Pseudokirchneriella
subcapitata) 72h EC50:
0.0426 - 0.0535 mg/L
(Pseudokirchneriella
subcapitata)
96h LC50: 0.0068 -
0.0156 mg/L (Pimephales
promelas) 96h LC50: =
0.112 mg/L (Poecilia
reticulata) 96h LC50: =
0.3 mg/L (Cyprinus
carpio) 96h LC50: = 0.8
mg/L (Cyprinus carpio)
96h LC50: = 1.25 mg/L
(Lepomis macrochirus)
96h LC50: = 0.052 mg/L
(Oncorhynchus mykiss)
96h LC50: = 0.2 mg/L
(Pimephales promelas)
96h LC50: < 0.3 mg/L
(Pimephales promelas)
48h EC50: = 0.03 mg/L
(b) Persistence and Degradability
No information available.
(c) Bioaccumulative potential
No information available.
(d) Other adverse effects
No information available.
13. Disposal considerations
(a) Waste treatment methods
Disposal methods
This material, as supplied, is not a hazardous waste according to Federal regulations (40
CFR 261). This material could become a hazardous waste if it is mixed with or otherwise
comes in contact with a hazardous waste, if chemical additions are made to this material,
or if the material is processed or otherwise altered. Consult 40 CFR 261 to determine
whether the altered material is a hazardous waste. Consult the appropriate state,
regional, or local regulations for additional requirements.
Contaminated Packaging
Dispose of contents/containers in accordance with local regulations
California Hazardous Waste
Codes
141
This product contains one or more substances that are listed with the State of California as a hazardous waste.
Chemical Name
California Hazardous Waste
Lithium Cobalt Oxide (CoLiO2)
12190-79-3
Toxic
Copper
Toxic