User guide

REPLACEMENT OF ACTUATOR
Retract tabs completely to relieve pressure. Inside transom, detach tubing from elbow, then unscrew elbow •
from pipe nipple. Remove pipe nipple.
Remove actuator from transom and put pipe nipple into new actuator dry. Do not over tighten. Two to three •
turns past hand tight is adequate. Do not use Teon tape.
Apply waterproof sealant on mounting surface and around nipple of new actuator. Insert through transom, •
keeping dirt out of the nipple, and secure actuator upper mount to transom with #14 x ½" screws.
(Note: Covering ends of nipples with masking tape will assure no dirt will enter nipple.)
Inside the transom, tighten the 90° elbow while holding nipples with channel locks. Use pipe compound or •
sealant on male threads only. Reattach nut w/ferrule. Do not over tighten.
Run tab up and down 2-3 times to purge air out of system. No bleeding is necessary.•