User Manual

10/ 2013
BENNING PV 1-1
16
7. Electrical specifications
Note: The measuring precision is specied as the sum of
- a relative fraction of the measured value and
- a number of digits (counting steps of the least signicant digit).
This specied measuring precision is valid for temperatures in the range from 18 °C to 30 °C and
relative humidity less than 80 %.
7.1 Protective conductor resistance R
PE
Measuring range Resolution Measuring accuracy
0.05 Ω - 199 Ω max. 0.01 Ω ± (2 % + 2 Digit)
Testing current:
> 200 mA (2 )
Open-circuit voltage:
> 4 V
Number of repetitive
tests (IEC 61557-2)
approx. 4000
7.2 PV module/ PV string, open-circuit voltage, (Vo/c)
Measuring range Resolution Measuring accuracy
5.0 V - 1000 V 0.1 V ± (0.5 % + 2 Digit)
7.3 PV module/ PV string, short-circuit current, (Is/c)
Measuring range Resolution Measuring accuracy
0.50 A - 14.99 A 0.01 A ± (1 % + 2 Digit)
7.4 Insulation resistance R
ISO
Measuring range Resolution Measuring accuracy
0.20 MΩ - 100 MΩ max. 0.01 MΩ ± (5 % + 5 Digit)
101 MΩ - 199 MΩ 1 MΩ ± (10 % + 5 Digit)
Testing voltage: 250 V
DC
/ 500 V
DC
/ 1000 V
DC
, + 20 %, - 0 %
Testing current:
> 1 mA, < 2 mA in case of a short-circuit
Number of repetitive
tests (IEC 61557-2)
approx. 2000
7.5 R
PE
voltage via 4 mm test sockets
Measuring range Resolution
Measuring accuracy
(DC, AC 50 Hz - 60 Hz)
30 V - 440 V AC/ DC 1 V ± (5 % + 2 Digit)
7.6 Current by means of AC/ DC current clamp adapter BENNING CC 3 (part no. 044038)
Measuring range Resolution
Measuring accuracy
(DC, AC 50 Hz - 60 Hz)
0.1 A - 40.0 A AC/ DC 0.1 A ± (5 % + 2 Digit)
8. Making measurements with the BENNING PV 1-1
8.1 Preparations for making measurements
Operate and store the BENNING PV 1-1 only at the specied storage and operating tempera-
tures conditions. Do not permanently expose the device to sunlight.
- Check rated voltage and rated current details specified on the safety measuring leads.
- Strong sources of interference in the vicinity of the BENNING PV 1-1 can lead to unstable
readings and measuring errors.
m
Before starting the BENNING PV 1-1, always check the device, the leads and
the test object for damages.
8.1.1 Switching the BENNING PV 1-1 ON/ OFF
- Press and hold the keys
2
and
3
for approx. 2 seconds to switch the BENNING PV 1-1 on.