Operation Manual
02/ 2011
BENNING IT 101
D F H I S
Bild 10: Gespeicherte Werte der
Isolationsmessung
Fig. 10: Stored values of the insulation
measurement
Fig. 10: Valeurs mémorisées de la mesure
d‘isolement
фигура 10: Съхранени стойности от изолационно
измерване
Obr. 10: Uložené hodnoty měření izolace
Εικόνα 10: Αποθηκευμένες τιμές της μέτρησης της
μόνωσης
10. ábra: Tárolt szigetelésmérési értékek
Ill. 10: Valori salvati di misurazione
dell‘isolamento
Fig. 10: Opgeslagen waarden van de
isolatiemeting
Rysunek 10:
Zapisane wartości pomiaru izolacji
Imaginea 10:
Valori memorate ale măsurării izolaţiei
Bild 10: Sparade värden från isoleringsmätningen
Bild 11: Gespeicherte Werte der DAR-Messung
Fig. 11: Stored values of the DAR measurement
Fig. 11: Valeurs mémorisées de la mesure
«DAR»
фигура 11: Съхранени стойности от DAR
измерване
Obr. 11: Uložené hodnoty měření DAR
Εικόνα 11: Αποθηκευμένες τιμές της μέτρησης DAR
(ρυθμός διηλεκτρικής απορρόφησης)
11. ábra: Tárolt DAR-mérési érték előhívása
Ill. 11: Valori salvati di misurazione del DAR
Fig. 11: Opgeslagen waarden van de DAR-meting
Rysunek 11:
Zapisanych wartości pomiarów DAR
Imaginea 11:
Valori stocate ale măsurării-DAR
Bild 11: Sparade värden från DAR-mätningen
9
Using the Store function
Store/Recall button :
The screen will be flashing MEM symbol and the number of
stored data twice when the Store/Recall button is pressed.
1. Press once to store the voltage value during voltage test
2. Press once to store the PI/ DAR, insulation or Earth-bond
resistance value when the individual test is completed.
3. The memory is divided into five segments,each segments
has 100 maximum data. The method to store the data is first
in /first out when the memory is full.
Table: The stored values of the individual test
segments
Items
Voltage
Earth-Bond
resistance
Insulation
resistance
50~1000V
DAR PI
1 Voltage Resistance Resistance
DAR
value
PI value
2
Leakage
current
R30-sec R1-min
3
Test voltage R1-min R10-min
Search the stored value under RECALL mode
NOTE :
Press the Store/Recall button ≧5 sec to clear the stored data.
The screen will be flashing MEM symbol and “ cLr ” on
reading twice.
Using the Recall function
Press the Store/Recall button ≧2 sec to enter/exit the RECALL
mode.
If the memory is empty, the meter will display the “nOnE ”
symbol.
10
Read the stored value of insulation test under
RECALL mode
Read the stored value of DAR test under
RECALL mode
Press the PI/DAR button ≧ 2 sec to choose the DAR
function, and Press the Store/Recall button ≧ 2 sec to enter
the RECALL mode.
10
Read the stored value of insulation test under
RECALL mode
Read the stored value of DAR test under
RECALL mode
Press the PI/DAR button ≧ 2 sec to choose the DAR
function, and Press the Store/Recall button ≧ 2 sec to enter
the RECALL mode.
Bild 9: Gespeicherte Messwerte aufrufen
Fig. 9: Calling stored measured values
Fig. 9: Appel des valeurs mesurées mémorisées
фигура 9: Извикване на съхранени измерени
стойности
Obr. 9: Vyvolání uložených naměřených hodnot
Εικόνα 9: Ανάκληση αποθηκευμένων τιμών
μέτρησης
9. ábra: Tárolt mérési érték előhívásal
Ill. 9: Visualizzazione dei valori salvati
Fig. 9: Opgeslagen meetwaarden opvragen
Rysunek 9: Przywołanie zapisanych wartości
Imaginea 9: Apelarea valorilor măsurate şi stocate
(memorate)
Bild 9: Hämta sparade mätvärden