Operation Manual

63
9.12 General data
Power supply voltage 9 V
DC
(6×1.5 V battery cells, size AA)
Power supply adapter 12 V - 15 V / 400mA
Operation typical 15 h
Plug commander (optional)
Overvoltage category CAT III / 300 V
Overvoltage category CAT III / 600 V, CAT IV / 300 V
Protectionclassication doubleinsulation
Pollution degree 2
Protection degree IP 42
Display 128x64 dots matrix display with backlight
Memory size 500 measurement results
Dimensions (w x h x d) 23 cm x 10.3 cm x 11.5 cm
Weight (without batteries) 1.17 kg
Reference conditions
Temperature range 10 °C - 30 °C
Humidity range 40% - 70 % RH
Operating conditions
Working temperature range 0 °C - 40 °C
Maximum relative humidity 95% 0 °C to 40 °C (non-condensing)
Storage conditions
Temperature range -10 °C to +70 °C
Maximum relative humidity 90% (-10 °C to + 40 °C)
80% RH (40 °C to 60 °C)
Theaccuracyisstatedfor1yearunderreferenceconditions.Thetemperaturecoefcientoutside
this limit value is 0.2 % of the measured value per °C and 1 digit.