Operation Manual

08/ 2012 13 / 58
BENNING ST 750 A
Go to the start menu and press <Setup> / <Expert Settings> to open the menu for entering the
password. Select <Test Procedures>. Then, select the corresponding <VDE Standard…>. Select
the device type (<Devices with PE (Class I)>, <Devices without PE (Class II)>, <SELV (Class
III)>).Allpredenedandcustomizedtestproceduresarelistedinthedrop-downlistbox.Keepthe
last number in mind to save the new test procedure under the next number (15 test procedures
are permanently stored internally). To copy, modify or delete a test procedure, the respective test
procedure must be selected (highlighted in blue)!
1. Creating a new test procedure:
After pressing <New Test Procedure>, enter a new number and name in the upper
field. If necessary, a pre-setting can be corrected by means of the <<--> button or
deleted by means of the <Clear> button. Select / enter the desired test parameters
in the main field. Press <Limit Values> to modify the limiting values (see chapter
7.1"Limiting Values") . After pressing <Back> in the "Test Procedure Setup" menu,
press <Save> / <Yes> to register a new test procedure in the drop-down list box.
Press <Back> to return to the start menu.
2. Copying a test procedure:
Select the test procedure to be copied and then press <Copy Test Procedure>. The further
proceeding is analogous to creating a new test procedure.
3. Modifying a test procedure:
Select the test procedure to be modified and then press <Modify Test Procedure>. The further
proceeding is analogous to creating a new test procedure. During the saving process of the
<Modify Test Procedure> option, it is indicated that the data record already exists and you will
be asked, if you want to overwrite it (<Yes> / <No>).
4. Deleting a test procedure:
Select the test procedure to be deleted and then press <Delete Test Procedure>. For the
<Delete Test Procedure> option, you will be asked, if you really want to delete the test
procedure (<Yes> / <No>).
7.5.3 Test Company / Person
Go to the <Expert Settings> menu to create or to modify the <Test Company / Person>. Test
company and test person are stored in the tester and will be saved in the database for each test!
In case of several test persons, implicitly check the settings!
7.5.4 Updating the Firmware
Thermwareisinstalled(update)viatheSDmemorycard.Thecorrespondinglesareprovidedby
BENNING.CopythisleontoanSDmemorycard(max.2GB).Afterhavinginsertedthememory
card,installthermwareupdateunder<Setup> / <Expert Settings> / <Firmware Update> and
conrmtheupdatewith<Yes>. After successful update, switch the device OFF and ON again.
7.5.5 Updating the User Interface
It is possible to install a software update via the USB interface or the SD card slot. The correspon-
dingles(Windows CE) are providedbyBENNINGina directory called "PicoMODX".Copythis
directory onto a USB stick. Switch the BENNING ST 750 A Appliance Tester ON. After inserting the
USB stick into the A jack, switch the BENNING ST 750 A Appliance Tester OFF and ON again. Now,
the device automatically installs the software. Remove the USB stick after completion. After suc-
cessful installation, the system settings in the setup program have to be made again.
For this purpose, successively select the following: <Setup> / <System Settings> / <System
Data>. Now, select e.g. the functions <Barcode Scanner>, <Mains Polarity Reversal ON>,
<Buzzer ON> and <Short-circuit Test ON>. Save the settings with <Save> and return to the start
menu by pressing <Back>.
7.5.6 System Reset
By pressing <Setup> / <Expert Settings> / <System Reset>, all system data will be reset. Con-
rmthe resetbypressing<Yes> / <No>. All limiting values and all user data will be reset to the
factory delivery status.
7.6 Date / Time
Gotothe"Setup Selection"menu,pressthe<Date / Time> button and enter the current values.
Use the input stylus to mark the corresponding numerical values and select the values / numerals.
Afterhavingnishedthesetting,pressthe<Save> button.